10

1. Reconnect the four (4) pin/socket connectors at the bottom of the right control box.

2. Reconnect the three (3) pin/socket connectors at the bottom of the left control box.

3. Reconnect the two (2) pin/socket connectors within the left control box.

4. Rewire the drive motor by inserting the three (3) black wires into the T1, T2, and T3 connections of the

Telemecanique drive contactor.

5. Rewire the blower (impellor/fan) motor by inserting the three (3) blue wires into the T1, T2, and T3

connections of the Telemecanique blower contactor.