10. COMMANDS
Protocol Syntax
Command Format: #
Example: #ACP1000
Sets Driver A to the current position of 1000
To query a command use the following format
Query Format: #
Example:
#AAC
Queries
Driver
A
for
the
current Acceleration Value
The response would be in the following format
Response Format: *
Example:
*AAC10
The Acceleration Value for Driver A is 10
characters to be typed in. For direct keyboard users, these values are executed when
the "Return" key is pressed. For programmers, a "Carriage Return" and "Line Feed"
(also known as a "New Line") command needs to be executed after each command.