R208 Microstepping Driver Manual
8/31/2007
8. MOTOR CONNECTIONS
 
Step Motors have 4, 6, or 8 wires. To better understand how to connect your step 
motor with your R208 Driver, follow the Figures below for the corresponding motor. 
NOTE: The dots indicate the starting position of the wires when wound. 
 
4 Lead Wire Motor Connection 
Connect one set of windings to the A terminals. Connect the other set of windings to 
the B terminals. If the set of windings is unclear, take a pair of wires; use an 
ohmmeter to check for continuity. When you find the first two wires that have 
continuity, connect it to the A terminals. Connect the other two to the B terminals. 
 
Figure 7.1: 4 Lead Wire Motor Connection
 
6 Lead Wire Motor Connection (Half Winding) 
Six wire motors can be wound in two ways: Half Winding and Full Winding. Six wire 
motors contain a center tap on each of the two windings. For a half-winding 
connection, the center tap and one end of the wires are used. 
 
Figure 7.2: 6 Lead Wire Half Winding Connection
 
6 Lead Wire Motor Connection (Full-Winding) 
For a full winding connection, use both end wires, the center tap is ignored. (NC: No 
Connection).