HOW TO INSTALL
NOTE: Top rail and Sliding Panels at each side are offset to provide the proper pitch to the rear of
(5/16 ). This is
Place unit on floor, a bench or a table. There is a Left and Right Window Filler Panel- be sure
to use the proper panel for each side. When installed the flange for securing the panel in place to
the window sill will be facing into the room.
necessary for proper condensed water utilization and drainage. If you are
not using the Side Panels for any reason, this pitch to the rear must be maintained.
,,
1
Fig.1
A. Hold the Accordion Panel
in one hand and gently
pull back the center to free
the open end. See Fig.1.
Fig.2A
Fig.2B
B. Slide the free and ( I section) of the panel
into the cabinet as shown in Fig. 2A, 2B & 3.
Slide the panel down. Be sure to leave enough
space to slip the top and bottom of the frame
into the rails on the cabinet.
C. Once the panel has been installed on the side
of the cabinet, make sure it sits securely inside
the frame channel by making slight adjustments.
Slide the top and bottom ends of the frame into
the top and bottom ends of the frame into the top
and bottom rails of the cabinet. Fig.4.
D. Slide the panel all the way in and repeat on the
other side.
NOTE: If storm window blocks AC, see Fig. 11.
Fig.3
Fig.4
8
end (“I” section )
NOTE: Top rail and sliding accordian panels at each side are offset to provide the proper ptich to the rear
of the unit (5/16”). This is necessary for proper condensed water drainage. If you are not using the sliding
accordian panels for any reason, this pitch to the rear of the unit must be maintained.
Place the unit on a solid surface. There is a Left and Right Window Filler Panel- be sure to use
the proper panel for each side. When installed, the flange that secures the panel to the window sill will be
facing into the room.