IMPORTANT NOTE:
If the gas supply fails to shut off
or if overheating occurs, shut off the gas valve to
the furnace before shutting off the electrical supply!
WARNING:
The furnace was shipped from the factory
equipped to operate on natural gas. Conversion
to LP/propane gas must be performed by a
licensed HVAC technician using a factory
supplied conversion kit. Failure to use the
proper conversion kit can cause fire, explosion,
property damage, carbon monoxide poisoning,
personal injury, or death.
WARNING:
All gas piping and shutoff valves must be
installed in compliance with local codes and
utility regulations by licensed installers. DO
NOT attempt to modify, or tap into existing
gas lines yourself. Fire or explosion may result
causing property damage, personal injury or
loss of life. Failure to follow the safety warnings
exactly could result in serious injury, death or
property damage.
VENTING SYSTEM
WARNING:
It is imperative to maintain proper operation
of the venting system, including the masonry
chimney (if applicable). Insufficient venting
could create the production of excessive
amounts of Carbon Monoxide (CO) - a colorless,
odorless gas that is produced during incomplete
combustion of any fuel. It can cause death
without warning. Carbon monoxide poisoning
can cause flu- like symptoms and also dizziness,
fatigue, headaches, nausea, and irregular
breathing.
If you suspect that you are experiencing CO
poisoning, get fresh air immediately. Leave the
home and call for assistance from a neighbor’s
home.
• The U.S. Consumer Product Safety Commission (CPSC)
recommends every home have a Carbon Monoxide
IMPORTANT SAFETY INFORMATION
WHAT TO DO IF YOU SMELL GAS
•
Do not try to light any appliance.
•
Do not touch any electrical switch; do not use
any phone in your building.
•
Leave the building immediately.
•
Immediately call your gas supplier from a
neighbors phone. Follow the gas suppliers
instructions.
•
If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Safety markings are used frequently throughout this
manual to designate a degree or level of seriousness and
should not be ignored.
WARNING indicates a potentially
hazardous situation that if not avoided, could result in
personal injury or death.
CAUTION indicates a potentially
hazardous situation that if not avoided, may result in minor
or moderate injury or property damage.
WARNING:
The safety information listed below must be
followed during the installation, service, and
operation of this furnace. Failure to follow safety
recommendations could result in possible
damage to the equipment, serious per
sonal
injury, or death.
WARNING:
PROPOSITION 65 WARNING:
This product
contains chemicals known to the state of
California to cause cancer, birth defects or other
reproductive harm.
WARNING:
This furnace is not approved for installation in
mobile homes. Installing this furnace in a mobile
home could cause fire, property damage, and/
or personal injury.
GAS SUPPLY & PIPING
This furnace does not have a pilot. It is equipped with
an ignition device which automatically lights the burner.
DO NOT light the burner by hand.