American Dryer Corp. AD-115ES II User Manual
Page 30

26
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is
affixed to the left side panel behind top/access control door. In the case of 208 VAC
or 240 VAC, the supply voltage must match the electric service specifications of the
data label exactly.
WARNING: 208 VAC AND 240 VAC ARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.
IMPORTANT: 380, 400, and 416 Volt dryers are built 4-wire only. Customer must contact the
factory to special order 3-wire systems.
ADE-115ES (60 Kw Electric Oven) Reversing, 3ø M otor
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC and 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY.
Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed
appliance amp draw data.
B. Circuit breakers are thermal-magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size
according to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3-phase (3Ø) dryers must be 3-pole type.
OVEN SIZE
(Kw)
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MINIMUM
WIRE SIZE
FUSING
CIRCUIT
BREAKER
60 Hz
50 Hz
Dual Element
Time Delay
60
208
3ш
3
181
--
*
250
250
60
240
3ш
3
159
161
*
200
200
60
380
3ш
4**
--
100
*
125
125
60
400
3ш
4**
--
95
*
125
125
60
416
3ш
4**
--
92
*
125
125
60
460
3ш
3
83
*
125
125
60
480
3ш
3
80
*
100
100
60
575
3ш
3
66
*
100
100
*AWG Stranded Wire Type...size wire as per National Electrical Code or local codes.
(Motor lead wire is recommended.)
**3-wire available.