beautypg.com

Rward (figure 6) – Ariens 991040 - Zoom 2660 HD User Manual

Page 18

background image

GB - 18

HYDRAULIC FLUID

Check Hydraulic Fluid Level

Check the system with the unit cold and
parked on a flat, level surface.

Then run the unit for about one minute and
recheck the levels.

To Add Hydraulic Fluid:

1. Remove the cap from the expansion

tank.

2. Fill the expansion tank with Mobil 1

Extended Performance 15W50 or
equivalent (Ariens p/n 00057100) until
oil level reaches the cold fill line on the
tank.

3. Install the expansion tank cap and then

purge the system. See Purging the
Hydraulic System
on page 19
.

Change Hydraulic Fluid and Filter

NOTE: Change hydraulic fluid and filter after
first 75 hours of operation. Change the
hydraulic oil filter and hydraulic oil every 400
hours. Use Mobil 1 Extended Performance
15W50 Synthetic Oil or equivalent for best
component life (Ariens p/n 00057100).

1. Place container under oil filter to catch

oil.

2. Remove the filter guard and oil filter from

the transaxle.

3. Remove the oil drain plug or fitting from

the inlet port and allow the transaxle to
drain completely.

4. Clean the filter mounting surface and

then lubricate rubber gasket on new oil
filter with clean hydraulic oil.

WARNING: HYDRAULIC FLUID
can result in severe burns. Fluid
in hydraulic system can penetrate
skin and result in serious injury or
death.
Be sure to stop the engine before
doing any work on hydraulic
parts.

Keep body and hands away from
pin holes or nozzles which expel
hydraulic fluid when under
pressure. Use paper or
cardboard, not hands, to search
for leaks.

Ensure all hydraulic fluid
connections are tight and all
hydraulic hoses and lines are in
good condition before applying
pressure to system.
FOREIGN FLUID INJECTED
INTO BODY can result in
gangrene. Fluid must be
surgically removed within a few
hours by a doctor familiar with
this form of injury.

1. Service

Position

2. Steering

Levers

3. Parking Brake
4. Battery

Figure 6

2

3

4

OM4110

1

2

Figure 7

The hydraulic fluid should be at the cold
fill line of the expansion tank.