beautypg.com

Lc47 s, Pecifications, Lc47 w – Glastender LC47 User Manual

Page 8: Iring, Iagram

background image

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780

800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com

5

lc47 s

Pecifications

LC47

S

tanDarD

F

eatures

• Modular lift-out refrigeration system for easy

in-field service

• High capacity refrigeration and recirculation for

high volume and remote long distance installations

• CFC-free R134a refrigerant

• Light-weight, roto-molded glycol bath with drain

• Polyurethane foamed-in-place insulation
NOTE: Clearance of 12” required around unit for

maximum air flow and 20” of overhead

clearance for servicing compressor.

Dimensions

• Height - 34.56” (87.7 cm)

• Width - 20.125” (51.1 cm)

• Depth - 25.125” (63.8 cm)

Electrical

• 230V, 1 phase, 60 Hz, 12.4 full load amps

• Dedicated 20 amp circuit is required

• Includes a 8-foot grounded cord

Refrigeration

• 3/4 HP R134a lift-out medium temperature con-

densing unit

Glycol Bath Capacity

• 16.25 U.S. gallons (61.78 l)

Maximum Distance to Taps

• 400 ft (91.5 m)

Circulating Pump

• 60 gph (227 lph)

Circulating Motor

• 1/3 HP (.25 kW)

Shipping Weight

• 155 lbs (70.34 kg)

Operating Weight

• 273 lbs (123.87 kg)

Shipping Cube

• 12.75 cu ft (.36 cu m)

Options

• Additional recirculating pump kit

• 4” Adjustable legs (up to 5-1/2”)

lc47 W

irinG

D

iaGram

BLACK

BLACK

BLACK

BLACK

BLACK

COMPRESSOR

RECIRC MOTOR

OPTIONAL

RECIRC MOTOR

GREEN

MAIN POWER

SUPPLY

230v/60hz

CONDENSER FAN

TERMINAL BLOCK

TERMINAL BLOCK

TEMPERATURE CONTRO

L

RED

BLACK

GREEN

RED

BLACK

GREEN

M

M

M

RED

RED

RED

RED

OVERLOAD

COMMON

RUN START

RELAY START

This manual is related to the following products: