Lc65 s, Pecifications, Lc65 w – Glastender LC47 User Manual
Page 4: Iring, Iagram
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
1
lc65 s
Pecifications
LC65
S
tanDarD
F
eatures
• Modular lift-out refrigeration system for easy
in-field service
• High capacity refrigeration and recirculation for
high volume and remote long distance installations
• CFC-free R134a refrigerant
• Light-weight, roto-molded glycol bath with drain
• Polyurethane foamed-in-place insulation
NOTE: Clearance of 12” required around unit for
maintenance and air flow.
Dimensions
• Height - 20.0” (49.5 cm)
• Width - 18.0” (45.7 cm)
• Depth - 25.75” (50.2 cm)
Electrical
• 115V, 1 phase, 60 Hz, 10.8 full load amps
• 230V, 1 phase, 50 Hz, 5.8 full load amps
• Dedicated 15 amp circuit is required
• Includes a 8-foot grounded cord
Refrigeration
• 1/3 HP R134a lift-out high temperature condensing unit
Glycol Bath Capacity
• 7.5 U.S. gallons (28.4 l)
Maximum Distance to Taps
• 125 ft (22.9 m)
Circulating Pump
• 60 gph (227 lph)
Circulating Motor
• 1/3 HP (.25 kW)
Shipping Weight
• 92 lbs (41.8 kg)
Operating Weight
• 152 lbs (69.1 kg)
Shipping Cube
• 9.5 cu ft (.28 cu m)
Options
• 4” Adjustable legs (up to 5-1/2”)
lc65 W
irinG
D
iaGram
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
COMPRESSOR
GREEN
GREEN
RECIRC MOTOR
OPTIONAL
RECIRC MOTOR
GREEN
MAIN POWER
SUPPLY
230v/60hz
CONDENSER FAN
TERMINAL BLOCK
TEMPERATURE CONTROL
M
M
M
RED
RED
RED
RED
RED
RED
OVERLOAD
COMMON
RUN START
RELAY START