Glastender GT-18 User Manual
Page 11
9
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
Your water supply fits one of the following descriptions.
Greater detergent consumption is required with “hard” water.
G
rainS
p
arTS
d
eScripTion
p
er
G
allon
p
er
m
illion
Soft
Less than 1.0
Less than 17.1
Slightly Hard
1.0 to 3.5
17.1 to 60
Moderately Hard
3.5 to 7.0
60 to 120
Hard
7.0 to 10.5
120 to 180
Very Hard
10.5 and over
180 and over
d
eTerGenT
T
iTraTinG
i
nSTrucTionS
An Alkalinity Test Kit, as recommended by your chemical supplier, is required for proper chemical adjustment.
Follow kit instructions to test.
S
aniTizer
T
iTraTinG
i
nSTrucTionS
Operate glasswasher to allow sanitizer levels to stabilize. With Conveyor removed and Conveyor Switch “On”,
dip Chlorine or Iodine test strip into Rinse Tank near Rinse Spray Box for one (1) second. Then immediately
compare the strip to the scale on the side of the test strip container tube. Adjust sanitizer (bleach) to 50 PPM,
and iodine type sanitizer to 12.5 PPM.
i
mporTanT
noTe
: Glasswashers are NOT water conditioners. Consult local water conditioning experts to
determine your specific water condition.
w
aTer
c
ondiTionS
u
SeFul
i
nFormaTion
a
bouT
w
aTer
, d
eTerGenT
,
and
S
aniTizer