7.0 TROUBLE-SHOOTING

Caution

Chart (Table 3) is used as a quick trouble shooting tool and mainly for reference only. It does not

mean to list all possible causes and solutions to the problems as seen by the user on Regulator. Contact
factory or authorize dealers for technical support and issues.

Table 3.

PROBLEM 

POSSIBLE CAUSE 

SOLUTION / RECOMMENDATION 

No Actuation 

No pilot pressure 

Provide pressure to pilot line 

Pilot line pressure blocked 

Only one pilot port may be pressurized at a time. 

Locking handle not tight 

Tighten handle with rubber mallet. 

Pilot line leaking 

Tighten or replace pilot line. 

External 
leakage 

Loose connections 

Tighten connections. 

Internal 
leakage 

Wear/Tear of pressure seals and O rings 

Replace with new Seals and O‐Rings. 

High Leakage 
Flow 

Slide Stuck, Pressure seals stuck or 
lifted 

Contact factory. 



7.1 MAINTENANCE INSTRUCTIONS

CAUTIONS
All repair of Barksdale ShearSeal® Regulators should be performed in a clean area free of excess dirt and
debris. The ShearSeal® components are manufactured to precise tolerances and can be damaged if proper care
is not taken.

WARNING
Isolate the regulator from all system pressure before performing any disassembly procedures.

Exploded view provided by Barksdale and/or distributor for reference only. It is strongly recommended that

all repairs and kit installations are completed by appropriately trained personnel. The customer will assume all
risk associated with the use of unauthorized parts or personnel.