Power Supply:
115/230VAC, 50/60Hz, switch selectable
Input Signal:
USITT DMX512
Outputs:
12 normally open or normally closed,
isolated contacts
Contact Rating:
5A at 30VDC
5A at 125VAC
3A at 277VAC
Connections:
Power & Relay: Two piece compression screw terminals
DMX in & thru: AMP MTA100 5-pin headers & screw
terminals
Size:
9.0” x 8.0” (203mm x 229mm)
Exceeding these ratings may result in personal injury
or damage to this and other connected devices.
MODE SELECT
1
2
3
All 12 relays maintained action
OFF
OFF
OFF
All 12 relays momentary action
ON
OFF
OFF
Six pairs, alternate action, momentary split
OFF
ON
OFF
Build Mode, one DMX channel
OFF
OFF
ON
X-Mode operation
ON
ON
OFF
Y-Mode operation
ON
OFF
ON
Momentary split c/w independent OFF
OFF
ON
ON
Reserved for future use
ON
ON
ON
ALL ON
5
Turn all relays on
ON
STATUS QUO
6
Five minute hold after loss of DMX signal
ON
Relays turn OFF 2 seconds after loss of DMX
OFF
MOMENTARY DURATION
4
7
250 msec.
OFF
OFF
500 msec.
OFF
ON
2.5 sec.
ON
OFF
TEST MODE
8
Each relay turned on when its address
(1-12) is dialed up on address switches
ON
DIP Switch Settings
For effects use, this unit can be set to Build Mode. In this
case all relays will respond to the single address set on
the rotary switches, depending on the DMX level for that
channel. The higher the level, the greater the number of
relays that will be on.
Build Mode
LCCC12 DMX Contactor
2 of 2
Technical support is available from Pathway Connectivity
at (403) 243-8110, Monday to Friday, from 9 a.m. to 5
p.m. Mountain time. Please have the unit model number
and serial number ready when you call.
Support
The Gray DMX Contactor is covered by a one year
warranty against defective parts and labor. If you need to
return anything for any reason, contact the factory in
advance for return instructions.
Warranty
A dual action momentary mode is available for use with
motors, screen and blind controls. These are situations
that require Up and Down, or Open and Close types of
commands. In dual action mode, the card operates as six
pairs of momentary relays (1 & 2, 3 & 4, etc.). When the
selected channel’s level is increasing and passes above
threshold, the first relay will close momentarily. When the
channel level is decreasing and passes below threshold,
the second relay will close momentarily.
Dual Action Momentary Mode
It is recommended that this device be mounted in a
secure electrical enclosure.
The device should be mounted using minimum 1/2” high
6-32 standoffs.
Do not exceed the maximum contact ratings.
Pathway Connectivity shall not be held responsible
for any injury or damage due to unsafe installation or
operation of this product.
Installation Notes
SPECIFICATIONS
rev4 ver1.4
09/03