Page 2

background image

Power Supply:

115/230VAC, 50/60Hz, switch selectable

Input Signal:

USITT DMX512

Outputs:

12 normally open or normally closed,
isolated contacts

Contact Rating:

5A at 30VDC
5A at 125VAC
3A at 277VAC

Connections:

Power & Relay: Two piece compression screw terminals

DMX in & thru: AMP MTA100 5-pin headers & screw

terminals

Size:

9.0” x 8.0” (203mm x 229mm)

Exceeding these ratings may result in personal injury
or damage to this and other connected devices.

MODE SELECT

1

2

3

All 12 relays maintained action

OFF

OFF

OFF

All 12 relays momentary action

ON

OFF

OFF

Six pairs, alternate action, momentary split

OFF

ON

OFF

Build Mode, one DMX channel

OFF

OFF

ON

X-Mode operation

ON

ON

OFF

Y-Mode operation

ON

OFF

ON

Momentary split c/w independent OFF

OFF

ON

ON

Reserved for future use

ON

ON

ON

ALL ON

5

Turn all relays on

ON

STATUS QUO

6

Five minute hold after loss of DMX signal

ON

Relays turn OFF 2 seconds after loss of DMX

OFF

MOMENTARY DURATION

4

7

250 msec.

OFF

OFF

500 msec.

OFF

ON

2.5 sec.

ON

OFF

TEST MODE

8

Each relay turned on when its address
(1-12) is dialed up on address switches

ON

DIP Switch Settings

For effects use, this unit can be set to Build Mode. In this
case all relays will respond to the single address set on
the rotary switches, depending on the DMX level for that
channel. The higher the level, the greater the number of
relays that will be on.

Build Mode

LCCC12 DMX Contactor

2 of 2

Technical support is available from Pathway Connectivity
at (403) 243-8110, Monday to Friday, from 9 a.m. to 5
p.m. Mountain time. Please have the unit model number
and serial number ready when you call.

Support

The Gray DMX Contactor is covered by a one year
warranty against defective parts and labor. If you need to
return anything for any reason, contact the factory in
advance for return instructions.

Warranty

A dual action momentary mode is available for use with
motors, screen and blind controls. These are situations
that require Up and Down, or Open and Close types of
commands. In dual action mode, the card operates as six
pairs of momentary relays (1 & 2, 3 & 4, etc.). When the
selected channel’s level is increasing and passes above
threshold, the first relay will close momentarily. When the
channel level is decreasing and passes below threshold,
the second relay will close momentarily.

Dual Action Momentary Mode

It is recommended that this device be mounted in a
secure electrical enclosure.
The device should be mounted using minimum 1/2” high
6-32 standoffs.
Do not exceed the maximum contact ratings.
Pathway Connectivity shall not be held responsible
for any injury or damage due to unsafe installation or
operation of this product.

Installation Notes

SPECIFICATIONS

rev4 ver1.4

09/03

Printed in Canada