CONTROL PANEL TOP VIEW
4. Turn the vac motor, and brush motor switches to the “I” position.
5. Set the pump switch to the “I” position. In the “I” position, the pump will only work when the
solution control lever is engaged.
6. On the lower left side of the machine, you can adjust the water flow by turning the ball
valve knob. Turning the knob clockwise reduces the water flow. Turning the knob
counter clockwise increases the water flow. When priming the pump, this knob should
be turned counter clockwise for maximum water flow.
7.
Attention: Do not let the pump function without water!
Using with Accessories
After filling the tanks with solution and plugging the power cable in to the wall outlet (see steps 1 and
2 of the paragraph SETUP), you need to perform the following operations:
1. Connect the machine to the wand or to the hand-tool using the solution and the vacuum hoses. To
connect the hoses to the machine, remove the vacuum hose, which connects the solution tank to
the vacuum shoe, and the solution hose.
PUMP
BRUSH
VACUUM
SOLUTION
CONTROL
I I
I
I
I
O O
O