Setting LOCK

10

11

Bodypack Transmitter

Bodypack Transmitter

LOCK

SET LOCK

UNLOCK

SET LOCK

SET

LOCKED

RF POWER

RF-HI

RF POWER

SET

MODE

!

Setting LOCK can be switched to LOCK or

UNLOCK mode.

!

Press MODE button until SET LOCK mode

appears.

!

Press SET button to select the desired

parameter.

!

Press MODE button to confirm and save the

change.

!

Press SET button twice to remove the LOCK

function.

!

The LOCK function will be removed automatically

when losing power.

!

Mute function can still work properly when

LOCK.

NOTE: Once locked, all 7 parameter values

cannot be changed.

ERR Message

!

When “ERR” appears in the display it indicates

that an operational error has occurred. Please

refer to the following codes to diagnose which

error you are experiencing.

ERR no01

EEPROM is not being programmed or

internal data error.

ERR no02

For testing only.

ERR no03

The frequency you want to program is

above the switching bandwidth of the

transmitter. Use a receiver with an

appropriate frequency group. (At this time

the microphone is still operating and the

frequency remains unchanged. To clear

the displayed "ERR" message, switch the

handheld transmitter off and on again.)

ERR no04

The frequency you want to program is

below the switching bandwidth of the

transmitter. Use a receiver with an

appropriate frequency group. (At this time

the microphone is still operating and the

frequency remains unchanged. To clear the

displayed “ERR” message, switch the

handheld transmitter off and on again.)

!

“Group” & “Channel”: When both the group

and channel numbers are displayed, it means

that you are using the pre-programmed

frequency of the receiver.

!

“Channel” Only: If “Channel” only is displayed,

it means that you are using a frequency which

is not pre-programmed.