Page 4

BATTERY STATUS
Indicates the power remaining in the transmitter
battery. When the battery has less than 10% power
remaining it must be replaced or recharged. If an
under voltage condition continues, the LCD will show
“Poff” and the system will shut down to prevent
being overly discharged.
“Poff” - Power Off :
100%
80%
40%
10%
0%
5
6
When the power switch is turned off, the LCD will
show “Poff” (for Power Off) first and then the system
will shut down and no further messages will be
displayed.
ERR
GROUP CHANNEL BAT
LCD SCREEN
!
ERR Message: When “ERR” appears in the display
it indicates that an operational error has occurred.
Please refer to the following codes to diagnose
which error you are experiencing.
ERR no01 EEPROM is not being programmed or internal
data error.
ERR no02 For testing only.
ERR no03 The frequency you want to program is above
the switching bandwidth of the transmitter.
Use a receiver with an appropriate frequency
group. (At this time the microphone is still
operating and the frequency remains
unchanged. To clear the displayed "ERR"
message, switch the handheld transmitter off
and on again.)
ERR no04 The frequency you want to program is below
the switching bandwidth of the transmitter.
Use a receiver with an appropriate frequency
group. (At this time the microphone is still
operating and the frequency remains
unchanged. To clear the displayed “ERR”
message, switch the handheld transmitter off
and on again.)
!
“Group” & “Channel” : When both the group
and channel numbers are displayed, it means that
you are using the pre-programmed frequency of
the receiver.
!
“Channel” Only: If “Channel” only is displayed, it
means that you are using a frequency which is not
pre-programmed.