Figure c figure b figure a – Crane Composites Sanigrid Fiberglass Ceiling Grid Class A User Manual
Page 3

A. Grid confi gured with main tees 4' O.C. and 4' cross tees interlocking main tees.
B. Grid confi gured with main tees 4' O.C. and 4' cross tees interlocking main tees and 2' cross tees (SG222) intersecting 4' tees.
C. Grid confi gured with main tees 2' O.C. and 2' cross tees (SG223) interlocking main tees.
IMPORTANT INSTALLATION NOTES
The main runner notches and cross tee lengths have been sized to 
provide a: 
23¾" x 47¾" (603 mm x 1213 mm) or 
23¾" x 23¾" (603 mm x 603 mm) 
opening at the top of the grid. 
As a result the main runners are 48" (1234 mm) on the center and 
the cross tees are 24¼" (616 mm) on center. This will provide 
clearance for laminated, rigid, or gypsum ceiling panels, light fi xtures 
or air diffusers. This may affect ceiling lay-out.
To accommodate the over-size dimensions of the Sanigrid II ceiling 
system, 23¾" x 48" (603 mm x 1219 mm) Glasbord
®
ceiling panels
are available and recommended. These panels WILL NOT FIT 
standard metal grid systems so they should be ordered only for 
Sanigrid II installations. 
The standard 23¾" x 23¾" (603 mm x 603 mm) panels will fi t the 
2' x 2' (0.6 m x 0.6 m) Sanigrid II system. 
Before beginning installation, ensure that you have the correct cross 
tee to match your ceiling layout. Two different 2' (0.6 m) cross tees 
are available. 
The SG222 is designed to mate with the 4' (1.2 m) cross tee. 
The SG223 is designed to mate with the 12' (3.7 m) main runner.
To accommodate light fi xtures and other ceiling inserts, the Sanigrid main 
runners are spaced 48.60" on center and the 4' cross tees are spaced 
24.25" on center. This spacing will provide a 23-3/4" x 47-3/4" or 
23-3/4" x 23-3/4" opening at the top of the grid. This may affect ceiling 
layout. Check component sizes (above and below) and center lines 
before laying out ceiling plan. This may also affect light fi xture positions 
and other trades above the ceiling line.
Light fi xtures must be supported independent of the ceiling grid system. 
Opening at face of grid for light fi xture lens door is 47" x 22-3/4" or 
22-3/4" x 22-3/4". 
CAUTION
When cutting, drilling, or grinding fi berglass materials, protect eyes with 
goggles. 
Wear a fi lter mask to avoid breathing dust, and wear gloves to prevent 
splinters.
A hacksaw is recommended for hand cutting ceiling system.
Figure C
Figure B
Figure A
Sanigrid
®
II Grid and Glasbord
®
Ceiling Panel Sizes
Grid Size
Glasbord Laminated Panel Thickness and Size Needed
5/8" | 15.9 mm
or less
3/4" | 19.1 mm
1" | 25.4 mm
and over
A
2′ x 4′ | 0.6 m x 1.2 m
23-3/4″ x 48″
0.6 m x 1.2 m
Not
Recommended for Sanigrid
23-3/4″ x 47-1/2″
0.6 m x 1.2 m
B
2′ x 2′ | 0.6 m x 0.6 m
23-3/4″ x 23-3/4″
0.6 m x 0.6 m
23-5/8″ x 47-1/2″
0.6 m x 1.2 m
C
2′ x 2′ | 0.6 m x 0.6 m
23-3/4″ x 24″
0.6 m x 0.6 m
23-5/8″ x 47-1/2″
0.6 m x 1.2 m