SANIGRID II PART NUMBERS

Wall Anchor Cross Tee #C-20

Wall anchors are available to secure the main runner and cross tees to the wall
angle. Also available is industrial double-faced tape that can be used in lieu of
screws to attach the wall anchor.

Main Tee Splice #C-21

The Main Tee Splice is used to securely join two main runners.

Ceiling Panel Hold Down Clip

#C-24 for panels 3/32" (2.4mm) - 9/32" (7.1mm)
#C-25 for panels 9/32
" (7.1mm) - 1/2" (12.7mm)
Hold down clips are intended only to hold ceiling panels in position. They will not
prevent panel warping under severe environmental conditions.

Rivet

#R52503 3/4" (19mm) #R52501 1" (25.4mm)
#R52502 1½
" (38mm) #R52507 2" (50.8mm)
Not included with standard installation kit, must be purchased separately.

Wall Angle #SG203

1" x 1" (25.4 mm x 25.4 mm) wall angles come cut in standard 12' (3.7 m) lengths to
fasten directly to the wall.

Main Runner #SG201

Main runners come in 12' 1½" (3.7 m) lengths.
Notches for cross tee attachments and hanger wires are 6-1/16" (154 mm) on center.

Cross Tee

#SG202 - 48½" (1232 mm) pre-notched to snap into the main runners.

Cross Tee 2’ - use with main runner

#SG223 - 24½” (622 mm) to mate with the main runners.

Cross Tee 2’ - use with 4’ cross tees

#SG222 - 24” (613 mm) nests between 4' cross tees.

PART #

IDENTIFIER

COLOR

LENGTH

DESCRIPTION

Sold in Full

Box/Bag

Quantities

R51512

White Only

12 ft.

SG201 - Main Tee

20

R51513

4 ft.

SG202 - 4 ft. Cross Tee*

30

R51514

2 ft.

SG222 - 2 ft. Cross Tee

30

R51522*

2 ft.

SG223 - 2 ft. Cross Tee (Main Tee Connection)*

30

R51519

12 ft.

SG203 -Wall Angle

20

R51516

Not

Applicable

C-20 -Wall Anchor

100

R51515

C-21 - Connector Clip

100

R51517

C24 - Hold-Down Clip panels 3/32” to 9/32”

100

R51518

C-25 - Hold-Down Clip for panels 9/32” to 1/2”

100

R51521

T-30 Double Face Tape to Attach Wall Anchor

100 ft. Roll

Reference Sanigrid Calculator at www.cranecomposites.com/industries/bp/ceilinggrid_confi g.html

*Cross Tee SG223 is designed to interlock with the main tee and is used only where main tees are spaced 2' on center. THESE TEES ARE A NON STOCKED
SPECIAL ORDER ITEM WITH A 4 WEEK LEAD TIME.

**Non-standard oversize ceiling panels (23.75" x 48" and 23.75" x 24" - use with 2ft cross tee SG223) are available to prevent ceiling panel from shifting. These
panels will not fi t standard metal grid systems.

Part Names and Numbers

$OORYHUOHQJWKGLPHQVLRQVKDYHDWROHUDQFHRIƍƍ

Wall Anchor

Cross Tee

C-20

Main Runner

Connection Clip

C-21

Tape

T-30

Ceiling Panel

Hold Down Clip

Ceiling Panel Thickness

C-24 |

ƍƍWRƍƍ

C-25 |

ƍƍWRƍƍ

Fits into

Main Runner

Fits into

ƍƍ&URVV7HH

Wall Angle

SG203

Main Runner

SG201

SG202

&URVV7HHƍ

SG223

SG222

&URVV7HHƍ

&URVV7HHƍ

H ƍ

Cross Tee

Connection Notch

Hanger Wire

Hole

ƍƍ2YHUDOO/HQJWK

ƍƍ2YHUDOO/HQJWK

ƍƍ2YHUDOO/HQJWK

ƍƍ2YHUDOO/HQJWK

ƍƍ2YHUDOO/HQJWK

ƍƍ

ƍƍ

ƍƍ

ƍƍ

ƍƍ

ƍƍ

ƍƍ

ƍƍ

ƍƍ

ƍƍ

ƍƍ

ƍƍ

ƍƍ

ƍƍ

Rivet

XVHZLWKPDLQUXQQHU

XVHZLWK¶FURVVWHH