Layout-m659-e12-xover 3/4, Good – Yorkville E12 User Manual
Page 7

3.
4.
CUT HERE
Coil Lead
Lead bent and leaned
against Teardrop Pad
PCB
5.
BAD
Place RTV points to fix leads on L1
GOOD
GOOD
L1, L2, L3, L4 Lead bending for soldering
BAD
COILS SEATED IMPROPERLY ARE TOO TALL, MAKING
INSERTION OF DISH INTO CABINET IMPOSSIBLE
SOMETIMES CAUSED WHEN INSERTING SCREWS IN WIRING
COILS SEATED PROPERLY ON BOARD
SEE LAYOUT DIAGRAM
6. L1 must be securely RTV'd to PCB
7. No RTV for C6 in Board Assembly - will be
RTV'd in wiring
8. #3854, Nylon Bolt, Must Use THIN Head Version
1. Bend Speakon legs to sit firmly on board.
2. Cut plastic on underside of coils as shown.
M659 PRODUCTION NOTES
RT
V
RT
V
RT
V
RT
V