Important, Manual reset hi-limit instructions – American Dryer Corp. AD-60 User Manual
Page 65

61
SECTION XI
MANUAL RESET HI-LIMIT INSTRUCTIONS
I M P O R T A N T
MANUAL RESET HI-LIMIT INSTRUCTIONS
FOR DUAL TIMER/MECHANICAL COIN OR PHASE 5 WITHOUT HEAT FAULT
(GAS MODELS ONLY)
This dryer was manufactured with a burner manual reset and basket (tumbler)/lint chamber hi-limit thermostat.
If either manual reset hi-limit thermostat is open prior to the start of the drying cycle, or during the cycle, the
dryer will not recognize the open state of the burner hi-limit thermostat and will start or continue through the
drying cycle with no heat. Manual reset hi-limit thermostat must be reset manually.
This hi-temperature condition may be caused due to a restricted exhaust, poor airflow, or improper burner
oven operation.
The location of the manual reset hi-limit switch is on the right side of the burner box.
IMPORTANT
This dryer is equipped with a burner
hi-limit and tumbler/lint chamber hi-limit
thermostat which must be reset manually.
WARNING: Discontinue power to dryer
before attempting to reset hi-limit.
ADC P/N:114093