Adg-60, Reversing, Gas) ads-60 – American Dryer Corp. AD-60 User Manual
Page 28: Steam), Electrical service specifications (per dryer)

24
IMPORTANT: Figures shown are for reversing models only. (For non-reversing models refer to the
previous page.)
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is
affixed to the upper left side panel area behind the top control (access) door. In the
case of 208 VAC or 230/240 VAC, the supply voltage must match the electric service
specifications of the data label exactly.
IMPORTANT: The wire size must be properly sized to handle the related current.
WARNING: 208 VAC AND 230/240 VAC ARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.
ADG-60
REVERSING
(Gas)
ADS-60
REVERSING
(Steam)
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC AND 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5
ONLY. Calculate/determine correct fuse value, by applying either local and/or National
Electrical Codes to listed appliance amp draw data.
B. Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others, calculate/
verify correct breaker size according to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
FUSING
CIRCUIT
BREAKER
Dual Element
Time Delay
208
3ш
3
5.0
15
15
240
3ш
3
5.4
15
15
380
3ш
3
3.4
15
15
416
3ш
3
3.6
15
15
460
3ш
3
3.3
15
15
575
3ш
3
---
15
15
380
3ш
3
3.4
15
15
416
3ш
4
3.6
15
15
460
3ш
4
3.3
15
15
480
3ш
4
3.3
15
15