The standard unit is equipped with an eight (8) foot power cord that requires a 115 Volt, 60 Cycle, 1 Phase

properly grounded electrical receptacle. The power cord comes with a 3 prong plug for grounding pur-

poses. Any attempt to cut off the grounding spike or to connect to an ungrounded adapter plug will void the

warranty, terminate the manufacturers responsibility and could result in serious injury.

The circuit must be protected with a 15 or 20 ampere fuse or breaker. The unit must be isolated on a circuit

and not plugged into an extension cord.

OPERATION

Initial Start Up

After satisfying the installation requirements, the unit is ready to start. The unit will start when the power

cord is connected to the required power source. If the compressor does not start when the unit is initially

plugged in, check to make sure that the temperature control is not in the "off " position. Allow the unit to run

a minimum of two hours before loading it with product. When loading the unit with product, take care not to

block the air flow at the back of the cabinet as this would affect the performance of the cabinet.

Temperature Control

The Temperature Control is located on the back wall of the cabinet liner and is factory set to maintain an

average cabinet temperature of 35 to 40 Deg. F. To obtain colder temperatures turn the Temperature

Control knob clockwise and visa versa. Allow the unit a minimum of one hour to respond to a control setting

adjustment.

Defrost

Your Silver King unit is an automatic defrost unit. No additional plumbing is required. The frost buildup on

the evaporator coil will clear each time the compressor shuts off and the condensate will drain to the

condensate evaporator pan where it will evaporate. It is important that the unit be level so the condensate

can drain properly.

MAINTENANCE

Preventative maintenance is minimal although these few steps are very important to continued operation

and maximizing the life of the appliance.

Cabinet Surfaces

The cabinet interior and exterior are stainless steel. These surfaces should be cleaned periodically with a

solution of warm water and mild soap and wiped dry with a soft cloth. Should a surface become stained, do

not attempt to clean with an abrasive cleaner or scouring pad. Use a soft cleanser and rub with the grain of

the metal to avoid scratching the surface.

Condenser

Periodically, dust on the condenser coil must be cleaned off. The condenser is located on the left side of

the front bottom grill. To clean it, remove the front bottom grill (2 screws) and simply vacuum the exposed

condenser coil or brush it to clear the accumulated debris. This will need to be done regularly to maintain