beautypg.com

Warning – Napoleon Fireplaces FIBERGLOW GLVF18 User Manual

Page 6

background image

6

W415-0809 / B / 01.07.11

2.3 GENERAL

INFORMATION

CARBON MONOXIDE POISONING MAY LEAD TO DEATH

EARLY SIGNS OF CARBON MONOXIDE POISONING RESEMBLE THE FLU, WITH HEADACHE, DIZZINESS

AND/OR NAUSEA. IF YOU HAVE THESE SIGNS, THE APPLIANCE MAY NOT BE WORKING PROPERLY.

GET FRESH AIR AT ONCE! HAVE APPLIANCE SERVICED.

SOME PEOPLE--PREGNANT WOMEN, PERSONS WITH HEART OR LUNG DISEASE, ANEMIA, THOSE

UNDER THE INFLUENCE OF ALCOHOL, THOSE AT HIGH ALTITUDES--ARE MORE AFFECTED BY

CARBON MONOXIDE THAN OTHERS.

THIS APPLIANCE MUST NOT BE INSTALLED IN A BEDROOM OR BATHROOM.

THE APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE.

THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES.

!

WARNING

For your satisfaction, this appliance has been test-fi red to assure its operation and quality!

This appliance is for installation in a solid fuel burning fi replace or listed ventless fi rebox enclosures only.

No external electricity (110 volts or 24 volts) is required for
the gas system operation.

This appliance is equipped with a pilot light safety system
referred to as an oxygen depletion sensor (ODS) and is
designed to turn off the appliance if not enough fresh air is
available.

Napoleon’s two vent free fi rebox enclosures the ZCVF
36/42 can be used to house all 3 of Napoleon’s vent free
log sets, the GVFL 18, 24 and 30.

We suggest that our gas
hearth products be installed
and serviced by profes-
sionals who are certified in
the U.S. by the National
Fireplace Institute

®

(NFI) as

NFI Gas Specialists.

www.nficertified.org

2.4 MINIMUM APPLIANCE SIZE

Each gas log set must be installed into a appliance cavity
with a minimum size.

Refer to the table to determine the appropriate minimum
appliance size.

LOG SET

HEIGHT

WIDTH

DEPTH

GVFL18

18”

24”

14”

GVFL24

18”

28”

14”

GVFL30

18”

34”

14”

GVFL18

GVFL24

GVFL30

NG

LP

NG

LP

NG

LP

Altitude (FT)

0-4,500

0-4,500

0-4,500

0-4,500

0-4,500

0-4,500

Max input (BTU/HR)

40,000

40,000

40,000

40,000

40,000

40,000

Min Inlet Gas Supply Pressure

4.5“ Water

Column

11“ Water

Column

4.5“ Water

Column

11“ Water

Column

4.5“ Water

Column

11“ Water

Column

Max Inlet Gas Supply Pressure

7“ Water

Column

13“ Water

Column

7“ Water

Column

13“ Water

Column

7“ Water

Column

13“ Water

Column

Manifold Pressure (Under Flow
Conditions)

3.5“ Water

Column

10“ Water

Column

3.5“ Water

Column

10“ Water

Column

3.5“ Water

Column

10“ Water

Column