3.4 OPTIONAL WALL SWITCH
For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient
location. Route a 2 strand, solid core millivolt wire from the valve to the wall switch or millivolt thermostat. The
recommended maximum lead length depends on wire size:
WIRE SIZE
MAX. LENGTH
14
gauge
100
feet
16 gauge
60 feet
18 gauge
40 feet
Disconnect the existing wires from terminals 1 and 3 (from the
ON/OFF switch) and replace with the leads from the wall switch / millivolt thermostat.
50.1
3
1
2
!
WARNING
DO NOT CONNECT EITHER THE WALL SWITCH, THERMOSTAT OR GAS VALVE DIRECTLY TO 110
VOLT ELECTRICITY.
3.5 MOBILE
HOME
29.2
Suitable for mobile home installation where the mobile home has been permanently placed on its site.
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where
not prohibited by local codes.
For mobile home installations, the appliance must be fastened in place. It is recommended that the appliance
be secured in all installations. See “REPLACEMENTS” section for the levelling / securing kit specifi c to your
appliance.
A.
Lift the top casting off the
unit.
B.
Loosen the securing bolts
on the cast front off of each
of the respective retainer
brackets (located at either
side on the top). Lift the
front casting off and place
the cast front face down on
a protective surface such as
a carpet or blanket to avoid
scratching the fi nished
surface.
C.
To re-install the front, repeat
in reverse order and ensure
bottom locating tabs engage
on either leg.
!
WARNING
FRONT / SCREEN MUST BE IN PLACE WHILE THE APPLIANCE IS IN OPERATION.
SCREEN
SECURING BOLTS
CAST FRONT
SECURING BOLTS
BOTTOM
LOCATING TABS
TOP
FRONT
RETAINER
!
WARNING
RISK OF FIRE!
NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.
DO NOT STRIKE, SLAM OR SCRATCH GLASS. DO NOT OPERATE APPLIANCE WITH GLASS
REMOVED, CRACKED, BROKEN OR SCRATCHED.
72.4
4.0 FINISHING
4.1 CAST FRONT REMOVAL
11
W415-0796 / C / 03.19.12