beautypg.com

Com port settings, Unit selection, Instructions – Anaheim PROGRAMMABLE SIMPLE INDEXER/DRIVER MBC10SI1 User Manual

Page 15: Direct talk mode

background image

15

#L010185

June 2007

Direct mode is used to directly control the motion for real time movements through serial communication.
The indexer has 14 commands which are easy to remember for direct movement of a step motor.

COM Port Settings

Baud Rate:

115200

Parity:

None

Data Bits:

8

Stop Bits:

1

Flow Control:Xon/Xoff

Unit Selection

In order to select a unit the @ command followed by 0 (address of the unit) must be sent.
NOTE: There should be no spaces between the @ and the 0.

How to select the unit:

@0

(Unit is selected)

How to get a response from the unit:

@0$

(Carriage Return)

After the $ command, the indexer will return a SMSI20 + the current version number.
Note: In direct talk mode each command is followed by a carriage return.

The unit communicates in half duplex mode, therefore proper setup of hyper terminal is necessary to view
characters, if characters are to be echoed back to the screen.

Instructions

All instructions require that no spaces be sent between the command and the parameter followed by a
carriage return. The commands are also case sensitive and are all sent as capitals.

Command Summary:

Direct Talk Mode

A - Acceleration/Deceleration
B - Base Speed
C - Current Reduction
G - Go (Index)
H - Hard Limit
M - Max Speed
N - Index Number

S - Soft Limit
T - Complete Time
V - Verify
+ - Clockwise Direction
- - Counterclockwise Direction
$ - Version Number Register
! - Error Codes Register