beautypg.com

General installation instructions, Specifications – APW Wyott Gas Hot Plate GHP-2H User Manual

Page 4

background image

"

2. GENERAL INSTALLATION INSTRUCTIONS:

Ensure gas supply and gas type, as shown on unit data plate agree. (Data plate is located on the right side

panel of unit).

Unit installation must conform with the National Fuel Gas Code, ANSI Z223.1-1996, the National Gas

Installation Code, CAN/CGA-B149.1, or the Propane Installation Code, CAN/CGA-B149.2 as applicable

and in accordance with local codes.

Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by hand. Level the

unit by turning the adjustment screw at the bottom of each leg. Do not slide unit with legs mounted, lift if

necessary to move unit.

Pipe gas supply to unit.

Pipe threading compound must be resistant to the action of liquefied petroleum gases.

These units are suitable for installation on combustible and noncombustible surfaces.

concealed, a claim must be made with the delivering carrier.

A) Apparent damage or loss must be noted on the freight bill at the time of delivery. It must then be signed by

the carrier representative (Driver). If this is not done, the carrier may refuse the claim. The carrier can supply

the necessary forms.

B) Concealed damage or loss if not apparent until after equipment is uncrated, a request for inspection

must be made to the carrier within 15 days. The carrier should arrange an inspection. Be certain to hold all

contents and packaging material.

Installation and start-up should be performed by a qualified installer who thoroughly read, understands and

follows these instruction.

If you have questions concerning the installation, operation, maintenance or service of this product, write

Technical Service Department APW Wyott Foodservice Equipment Company, P.O. Box 1829, Cheyenne,

WY 82003.

!

!

Warning: DO NOT use an open flame to check for leaks. Check all gas piping for leaks

with a soap and water solution before operating unit.

3. SPECIFICATIONS

These units are suitable for installation on

NON-COMBUSTABLE surfaces only.

NON-COMBUSTABLE CLEARANCES

Sides

Rear

Floor

0”

6”

4”

3.141

1.637

9.000

13.626

6.144

9.141

12.137

3.846

4.348

18.500

6.241

28.754

1.825

8.035

11.049