beautypg.com

Specifications, Preparation for operation, Operating – ATN MArs x4 User Manual

Page 3

background image

2

spEcIfIcATIons

pREpARATIon foR opERATIon

Before getting started make sure to follow these steps:
• Install the battery into its housing with the polarity order

shown on the main body of the unit. The CR123A battery

used with adapter. Install adapter first, then CR123A . AA

battery used without adapter.
• Switch on the scope with the protective lens cover still

attached to the lens.
• Make sure that the green luminance of the light intensifier

tube is present.
• Observe the scene, and adjust the diopter and/or lens for

optimal image clarity.
• You may now enter a dark environment or simply shut the

lights off in order to darken the room.
• Next, remove the lens cap/daylight filter.

opERATIng

mounTIng

1. Mount the PS-22 with Adapter onto the A.R.M.S.#10 or A.R.M.S.#19 ACOG with 2 screws M5x8.
2. Unscrew the protective back cap from PS-22.
3. Screw the Light Screen into the thread in back side of unit.
4. Slightly loosen the fixing screws or levers of mount.
5. Place the PS-22 on the weaver rail of the fire arm before objective of daytime scope on the

minimal distance from it. The optical axes of PS-22 and daytime scope must have diver-

mARs X4

2nd, 2nd+, 3rd, 4th

F1:1.5

4X

9 deg.

10 m to

45mm

7mm

-6/+2

120MOA

1/4MOA

one 3V (CR123A) or 1.5V (AA)

Super 450mW

-51°C to +45°C

55 (3V)/ 40 (1.5V )hours

20m for 1 hour

Red or Amber On Green

235x90x95mm

1.3kg

Generation .............................
Lens of system ..........................
Magnification ..........................
FOV ..........................................
Range of focus .........................
Eye relif .....................................
Exit pupil ...................................
Diopter adjustment ...............
Windage & elevation ................
Adjustment step size ..............
Power supply ........................
IR illuminator ............................
Operating temperature .......
Battery life................................
Waterproof ...............................

Reticle ....................................

Dimensions .............................
Weight ....................................

mARs X6

2nd, 2nd+, 3rd, 4th

F1:2.0

6X

6 deg.

25 m to

45mm

7mm

-6/+2

80MOA

1/6MOA

one 3V (CR123A) or 1.5V (AA)

Super 450mW

-51°C to +45°C

55 (3V)/ 40 (1.5V )hours

20m for 1 hour

Red or Amber On Green

295x95x100mm

1.55 kg

Battery cap

Battery cap

AA

battery

CR123A

battery

Battery

adapter

This manual is related to the following products: