beautypg.com

Ype of – American Dryer Corp. ADG-758 User Manual

Page 29

background image

25

2. Technical Gas Data

a. Gas Specifications

b. Gas Connections:

Inlet connection ---------- 3/4-inch N.P.T.
Inlet supply size ----------- 3/4-inch N.P.T. (minimum)

Btu/hr input (per dryer) -- 175,00 (44,100 kcal/hr)

1) Natural Gas

Regulation is controlled by the dryer's gas valve's internal regulator. Incoming supply pressure must
be
consistent between a minimum of 6.0 inches (14.92 millibars) and a maximum of 12.0 inches water
column (W.C.) - 29.9 millibars - pressure.

2) Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve's internal pressure regulator blocked open so
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas
valve pressure tap must be a consistent 10.5 inches water column (W.C.) - 26.1 millibars. There is no
regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at the
source (L.P. tank) or an external regulator must be added to each dryer.

T

YPE OF

G

AS

Natural

Liquid Propane

Manifold Pressure*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

Inline Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

10.5 inches W.C.

26.1 mb

Shaded areas are in metric equivalents

* Measured at gas valve pressure tap when the gas valve in on.

T

YPE OF

G

AS

L.P.

Conversion Kit

Part Number

ADC

MODEL

NUMBER

Rating

Rating

Natural

Liquid Propane

Qty. D.M.S.*

Number

Qty. D.M.S.*

Part

Number

ADG-

758

1

75

,000

44,100

4

#

30

140

819

4

#49

140803

8

82230

Shaded area is stated in metric equivalent

* D.M.S. (Drill Material Size) equivalents are as follows:

Natural Gas ............... #30

= .1285" (.33 cm)

Liquid Propane Gas .. #49

= .0730" (.19 cm)