beautypg.com

Specifications – Panasonic 36PSU1U6 User Manual

Page 94

background image

1-88

1. Specifications

6-17. Shaping the Tubing

(1) Shape the refrigerant tubing so that it can easily go

into the hole. (Fig. 1-45)

(2) Push the wiring, refrigerant tubing and drain hose

through the hole in the wall. Adjust the indoor unit

so it is securely seated on the wall fixture.

(3) Carefully bend the tubing (if necessary) to run along

the wall in the direction of the outdoor unit and then

insulate to the end of the fittings. The drain hose

should come straight down the wall to a point where

water runoff will not stain the wall.

(4) Connect the refrigerant tubing to the outdoor

unit.(After performing a leak test on the connection,

insulate it with insulating tape. (Fig. 1-46))

(5) Assemble the refrigerant tubing, drain hose and

inter-unit wiring as shown in Fig. 1-47.

6-18. Installing the Drain Hose

(1) The drain hose should be slanted downward on the

outdoor side. (Fig. 1-48)

(2) Never form a trap in the course of the hose.

(3) If the drain hose will run in the room, insulate* the

hose so that chilled condensation will not damage

furniture or floors. (Fig. 1-49)

* Foamed polyethylene or its equivalent is

recommended.

Cover

Refrigerant
tubing

Inter-unit
wiring

Drain hose

Fig. 1-45

Insulating
tape

Fig. 1-46

Refrigerant tubing

Inter-unit wiring

Drain hose

Fig. 1-47

WARNING

Do not supply power to the unit

or operate it until all tubing and

wiring to the outdoor unit are

completed.

Drain
hose

Slant

Indoor
unit

Fig. 1-48

Condensation

Insulation material
(field supply)
must be used.

Fig. 1-49

1

SM830203-01_PAC-i_US-letter.indb88 88

SM830203-01_PAC-i_US-letter.indb88 88

2012/01/19 22:39:31