Installation – Alliance Laundry Systems HC35 User Manual
Page 53
51
Installation
F232062
If the machine fails to operate after power is
connected, disconnect power and check the
control circuit fuse. Unlock and raise the top
cover. For mechanical timer, P-computer, and
S-computer models, the control circuit fuse is
on the center brace. For EDC and V-computer
models, dual control circuit fuses (1 primary
and 1 secondary) are in the control module. A
decal identifies the fuse (or fuses) in each case,
and provides the fuse rating appropriate to that
specific model.
If the control circuit fuse has blown, replace
with a fuse of the appropriate rating as
identified by the decal. Call a qualified
electrician if the replacement fuse blows.
Cabinet Hardmount
Electrical Specifications
80-Pound Capacity Models
Voltage Designation
Standard
Electric Heat
Code
Vo
lt
a
g
e
Cyc
le
P
h
ase
Wi
re
Full Loa
d
Am
p
s
Cir
c
uit
Br
eake
r
AW
G
mm
2
Full Loa
d
Am
p
s
Cir
c
uit
Br
eake
r
AW
G
mm
2
3-Speed Models
A
208-240
60
3
4
15
40
6
16
90
100
1
45
C
380-415
50
3
4
9
20
12
4
41
45
6
16
D
220-240
50
3
3
14
40
6
16
89
90
2
35
F
440-480
60
3
3
9
20
12
4
46
50
6
16
O
208-240
60
3
3
15
40
6
16
90
100
1
45
W
380-415
50
3
3
9
20
12
4
41
45
6
16
Variable-Speed Models
F
440-480
60
3
3
4.49
15
14
2.50
N/A
O
208-240
60
3
3
12.4
20
12
4
87.46
90
2
35
Note: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.