2. Technical Gas Data

a. Gas Specifications

* Measured at gas valve pressure tap when the gas valve is on.

b. Gas Connections

Inlet connection --- 3/4” N.P.T.
Inlet supply size --- 3/4” N.P.T. (minimum)
Btu/hr input -------- 204,000 (51,408 kcal/hr)

1) Natural Gas

Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure
must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches
(29.9 mb) water column (W.C.) pressure.

2) Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas
valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no regulator
or regulation provided in an L.P. dryer. The water column pressure must be regulated at the source
(L.P. tank) or an external regulator must be added to each dryer.

* Drill Measurement Size (D.M.S.) equivalents are as follows:

Natural Gas ......................... #23 = 0.1540” (3.9116 mm).
Liquid Propane Gas ............. #42 = 0.0935” (2.3749 mm).

TYPE OF GAS

L.P.

Conversion Kit

Part

Number

ADC

MODEL

NUMBER

BTU

Per Hour

Rating

kcal/hr

Rating

Natural

Liquid Propane

Qty. D.M.S.*

Part

Number

Qty.

D.M.S.*

Part

Number

AD-78

204,000

51,408

3

#23

140856

3

#42

140810

881655

Shaded area is stated in metric equivalent

TYPE OF GAS

NATURAL

LIQUID PROPANE

Manifold Pressure*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

In-Line Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

11.0 inches W.C.

27.4 mb

Shaded areas are stated in metric equivalents