Alliance Laundry Systems CHM166C User Manual
Page 23

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation/Operation Supplement
21
F232145 (EN)
Electrical Specifications
35 Pound Capacity Models
Voltage Designation
Standard
Electric Heat
Code
Vo
lt
a
g
e
Cyc
le
P
h
ase
Wi
re
Fu
ll Lo
a
d
Am
ps
Ci
rc
uit
B
rea
ker
AW
G
mm
2
Fu
ll
L
o
ad
Am
p
s
Ci
rc
uit
B
rea
ker
AW
G
mm
2
2 Speed Models
C
380 – 415
50
3
4
5
15
14
2.5
26
30
10
6
D
220 – 240
50
3
3
7
20
12
4
43
50
6
16
F
440 – 480
60
3
3
5
15
14
2.5
26
30
10
6
O
200 – 240
60
3
3
7
20
12
4
43
50
6
16
Y
208 – 240
60
1
2
12
25
10
6
N/A
Variable-Speed Models
N
440 – 480
50/60
3
3
2.3
15
14
2.5
27.3
30
10
6
P
380 – 415
50/60
3
3
2.3
15
14
2.5
24
25
10
6
Q
208 – 240
50/60
3
3
5.9
15
14
2.5
43.4
45
6
16
T
200 – 240
50/60
1
2
5.9
15
14
2.5
N/A
X
200 – 240
50/60
1 or 3 2 or 3 5.9/5.9
15
14
2x2.5
3x2.5
N/A
NOTE: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.
Table 9
Electrical Specifications
40 Pound Capacity Models
Voltage Designation
Standard
Electric Heat
Co
d
e
Vo
lt
a
g
e
Cy
c
le
Ph
a
s
e
Wi
re
Ful
l Loa
d
Am
p
s
Ci
rc
u
it
B
rea
ke
r
AW
G
mm
2
Fu
ll
L
o
a
d
Amps
Ci
rc
u
it
B
rea
ke
r
AW
G
mm
2
2 Speed Models
C
380 – 415
50
3
4
5
15
14
2.5
26
30
10
6
D
220 – 240
50
3
3
7
20
12
4
45
50
6
16
F
440 – 480
60
3
3
5
15
14
2.5
29
30
10
6
H
380
60
3
3
3
15
14
2.5
25
30
10
6
J
200
50
3
3
7
20
12
4
38
40
6
16
O
208 – 240
60
3
3
7
20
12
4
45
50
6
16
Y
208 – 240
60
1
2
13.5
30
10
6
N/A
Variable-Speed Models
N
440 – 480
50/60
3
3
6
15
14
2.5
30
30
10
6
P
380 – 415
50/60
3
3
6
15
14
2.5
29
30
10
6
Q
200 – 240
50/60
3
3
5
15
14
2.5
48
60
6
16
X
200 – 240
50/60
1 or 3 2 or 3
11/11
15
14
2.5
N/A
NOTE: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.
Table 10