Long-Form Report page #1
IEC 1000-3-2/EN 61000-3-2 Fluctuating Current Harmonics Test
Date Performed: 05/10/96
Test Executed By: A.C. Testright
Company Name: True Test Laboratories
Device Under Test ID: Model 12345 Modular Power Supply
Test ID: 00123
Approved by: QA
Signature:________________________________________________________ Date:__________________
Final Test Result: FAIL
Settings and Test Conditions Compliant to the Standard: Yes
Test Equipment Used:
Agilent 6842A Harmonic/Flicker Test System with serial number 3440A-00101
Agilent 14761A HFTS software Version: A.00.05
Date Last Calibrated: June 6, 1997
Test Equipment Settings:
------------------------
Line Voltage: 230.00 V
Current Measurement Range: High
Line Frequency: 50 Hz
Measurement Window Type: Rectangular
Device Class: D
Measurement Delay: 10.0 seconds
RMS Current Limit: 13.1 A
Fluctuating Test Duration: 2.00 minutes
Peak Current Limit: 80.8 A
Class Determination Pre-test Duration: 10.00 seconds
Number of Records: 375
Overrides:
----------
Test Limit Source (Power Measurements/Statistics): Maximum
Power Overrides: None
Test Limit Overrides: None
Pre-test Results for Class Determination:
-----------------------------------------
Percent in Envelope: 100.0%
Voltage THD Out-of-Specification?: No
Class D Equipment?: Yes
Fundamental Current: 1.343 A
RMS Voltage: 229.8 V
RMS Current: 1.7 A
Real Power: 148.8 W
Frequency: 50.0 Hz
Peak Current: 5.2 A
Apparent Power: 384.2 VA
Voltage THD: 0.10%
Current THD: 80.68%
Power Factor: 0.387
Maximum Power: 148.8 W
Mean Power: 146.7 W
Active Power Statistics:
------------------------
100th percentile: 148.8 W
99th Percentile: 147.3 W
95th Percentile: 147.3 W
90th Percentile: 147.3 W
50th Percentile: 146.2 W
Total Number of Failures:
Total Number of Errors:
-------------------------
-------------------------
4505 Failures
None