Product specification – Panasonic CURE9NKE User Manual
Page 68

68
69
Indoor Unit
Outdoor Unit
Model
CS-RE9NKE
CU-RE9NKE
CS-RE12NKE
CU-RE12NKE
CS-RE15NKE
CU-RE15NKE
COOL
HEAT
COOL
HEAT
COOL
HEAT
Single, 230V,50Hz
Single, 230V,50Hz
Single, 230V,50Hz
Power/Current
[kW]
0.700
0.820
1.010
1.120
1.260
1.385
[A]
3.30
3.80
4.70
5.20
6.00
6.30
Refrigerant
[kg]
R410A
0.640
R410A
0.780
R410A
0.920
Cooling Capacity
[kW]
2.50
3.50
4.20
Heating Capacity
[kW]
3.30
4.25
5.00
Noise Level
JIS C 9612
[<70 dB(A)]
[dB(A)]
42
42
42
42
46
46
Conditions
1m Distance
Max. cooling/
heating
operation
47
48
48
50
50
51
Sound power
level
[dB(A)]
58
58
58
58
62
62
63
64
64
66
66
67
Air Circulation
[m
3
/min.]
12.5
11.1
12.5
12.5
14.8
14.5
kg
Product Weight
[kg]
8.0
8.0
8.0
20
26
27
Dimensions (H x W x D)
[mm]
290 x 848 x 213
290 x 848 x 213
290 x 848 x 213
530 x 720 x 275
540 x 780 x 289
540 x 780 x 289
PRODUCT SPECIFICATION
1. Standard piping length: 5 m.
2. Air filters are attached.
00 F568363_COVER.indd 68
2012-2-10 11:06:27