(f) Software version enquiry (Scaler)
Syntax
Header
Category
Function
Data1
Data2
Check Sum
Enquiry
0x83
0x30
0x0F
0xFF
0xFF
0xC0
(Code Table(4-d)[a])
Answer
Header
Answer
Return to Data Size
Return Data1
Return Data2
Check Sum
Enquiry
0x70
0x00
0x03
Upper 8bit Data
Lower 8bit Data
0xXX
Completed
Return Data1 - Data2: 0x0000 - 0xFFFF
Example)
For version 1.000, they become 10 and 00, respectively.
(g) Shutdown Log enquiry
Syntax
Header
Category
Function
Data1
Data2
Check Sum
Enquiry
0x83
0x30
0x11
0xFF
0xFF
0xC2
(Code Table(4-d)[a])
Answer
Header
Answer
Return to Data Size
Return Data1
Check Sum
Enquiry
0x70
0x00
0x02
Code Table(4-c)
0xXX
Completed
Return Data1: 0x00 - 0xFF
Code Table(4-c)
Shutdown Information
bit0
Reserved
bit1
1: FAN operation is abnormal
0: Normal
bit2
1: Backlight is abnormal
0: Normal
bit3
1: Temperature sensor is abnormal
0: Normal
bit4
1: Main power supply is abnormal
0: Normal
bit5
1: Digital power supply is abnormal (3.3 V, 5 V) 0: Normal
bit6
1: Analog supply is abnormal (5 V/9 V)
0: Normal
bit7
1: Scaler is abnormal
0: Normal
Code Table(4-d)
[a]Function
[b]Range/Switch code
Command
Control
Enquiry
Standby
Power On
0x00
Model Name
0x0A - 0x0B
No
Yes
Enable
Enable
0x01
Serial Number
0x001E8480 - 0x002DC6BF
Yes
Yes
Enable
Enable
(2,000,000 - 2,999,999)
0x02
Operation Time
0x00000000 - 0xD693A3FF
(0sec.
_
3,599,999,999sec.)
0x03
Soft Version(Main)
0x0000 - 0xFFFF
No
Yes
Enable
Enable
0x07
Digital 3.3 V
0x00 - 0xFF
0x09
Digital 5 V
0x00 - 0xFF
0x0A
Temp1
0x00 - 0xFF
0x0D
Temp(P/S)
0x00 - 0xFF
0x0F
Soft Version(Scaler)
0x0000 - 0xFFFF
0x10
Analog5 V/9 V
0x00 - 0xFF
(Continued)