OEL = Occupational exposure limit

Maintenance, cleaning and
repair

During the following work, ensure that dust is not unnecessarily
spread around. Wear a P2 breathing mask.
CAUTION: In the case of asbestos abatement wear additional sin-
gle-use clothing.

Only carry out maintenance work described in the operating instruc-
tions.

Always pull out the mains plug before cleaning and maintenance of
the vacuum cleaner.

During maintenance and cleaning, handle the vacuum cleaner in
such a manner that there is no danger for maintenance staff or other
persons.

In the maintenance area
1. Use filtered compulsory ventilation
2. Wear protective clothing
3. Clean the maintenance are so that no harmful substances get

into the surroundings

Before removing the vacuum cleaner from the area contaminated
with harmful substances:
1. Clean the outside of the vacuum cleaner, wipe it clean or pack

the vacuum cleaner in well sealed packaging

2. and avoid spreading deposited harmful dust.

After use, in asbestos contaminated areas, the machine must be
cleaned by an authorised person according to TGRS 519.

Extension lead

As an extension lead, only use the version specified by the manufac-
turer or one of a higher quality.
When using an extension lead, check the minimum cross-sections
of the cable:

Cable length

Cross section

< 16 A

< 25 A

up to 20 m

1.5 mm

2

2.5 mm

2

20 to 50 m

2.5 mm

2

4.0 mm

2

Electrical connection

1. It is recommended that the vacuum cleaner should be connected

via a residual current circuit breaker.

2. Arrange the electrical parts (sockets, plugs and couplings) and

lay down the extension lead so that the protection class is main-
tained.

3. Connectors and couplings of power supply cords and extension

leads must be watertight.