Reliability condition, 1. temperature condition, Recommended connector – DMC FST Series User Manual
Page 7: 1. recommended connector
DER-S0096A
7
Rev. 5 ©2005 - 2013 DMC Co., Ltd.
FST Series Product Specifications
3. Reliability Condition
3-1. Temperature Condition
§ Temperature Condition Test
Following test are performed in the condition with no dew condensation:
Cold Test:
Tested after leaving the parts in -40°C
3°C for 240 hours and in the room temperature
for 2 hours.
Heat Test:
Tested after leaving the parts in 80°C
3°C for 240 hours and in the room temperature for
2 hours.
Humidity Test: Tested after leaving the parts in the temperature 60°C
3°C, humidity 90 to 95% for 240
hours and in the room temperature for 2 hours.
Cycle Test:
Tested after 5 cycles of leaving the parts in the temperature -30°C
3°C for 1 hour and in
the room temperature for 0.5 hours, then leaving the parts in the temperature 70°C
3°C
for 1 hour and in the room temperature for 0.5 hours.
Judgement:
Must satisfy the following:
Activation Force:
Must satisfy the specification.
Linearity:
Must satisfy the specification.
Terminal Resistance:
Must satisfy the specification.
Insulation Resistance:
Must satisfy the specification.
Appearance:
Must satisfy the specification.
4. Recommended Connector
4-1. Recommended Connector
Part No.
Manufacturer
Pitch
Remarks
RE-H052SD-1110
J.S.T. Mfg Co., Ltd
2.54mm
equivalent