3. Reliability Condition

3-1. Temperature Condition

§ Temperature Condition Test

Following test are performed in the condition with no dew condensation:

Cold Test:

Tested after leaving the parts in -40°C

3°C for 240 hours and in the room temperature

for 2 hours.

Heat Test:

Tested after leaving the parts in 80°C

3°C for 240 hours and in the room temperature for

2 hours.

Humidity Test: Tested after leaving the parts in the temperature 60°C

3°C, humidity 90 to 95% for 240

hours and in the room temperature for 2 hours.

Cycle Test:

Tested after 5 cycles of leaving the parts in the temperature -30°C

3°C for 1 hour and in

the room temperature for 0.5 hours, then leaving the parts in the temperature 70°C

3°C

for 1 hour and in the room temperature for 0.5 hours.

Judgement:

Must satisfy the following:
Activation Force:

Must satisfy the specification.

Linearity:

Must satisfy the specification.

Terminal Resistance:

Must satisfy the specification.

Insulation Resistance:

Must satisfy the specification.

Appearance:

Must satisfy the specification.

4. Recommended Connector

4-1. Recommended Connector

Part No.

Manufacturer

Pitch

Remarks

RE-H052SD-1110

J.S.T. Mfg Co., Ltd

2.54mm

equivalent