beautypg.com

Alto-Shaam Halo Heat 1200-UP User Manual

Page 20

background image

1200-S, 1200-UP •

INSTALLATION

/

OPERATION

/

SERVICE MANUAL

-

PG

. 19

T H E R M O S T A T A C C U R A C Y

S E R V I C E

The electronic thermostat is a precise

instrument and is designed to offer trouble free

service. If you suspect the temperature inside

the holding compartment does not match the

temperature indicated on the digital display,

follow the instructions listed below.
1.

Check to make certain the unit voltage

matches the power source. A power source

less than that required to operate the unit

will result in inaccurate temperatures.

2.

Verify the temperature inside the holding

compartment with a qualify thermal

indicator.

A.

With the exception of the wire shelves,

completely empty the holding

compartment.

B.

Make certain the holding cabinet sensor,

located inside the holding compartment

at the left side of the unit, is completely

clean.

C.

Suspend the thermal indicator in the

center of the holding compartment.

D.

Allow the temperature set on the

electronic thermostat to stabilize for a

minimum of one hour before comparing

the digital display with the reading on

the thermal indicator.

DO NOT OPEN THE CABINET DOOR(S)

DURING THE TEMPERATURE

STABILIZATION PERIOD.

If the reading on the thermal indicator does not

match the digital display, there may be a

problem with the air sensor. See

troubleshooting guide in this manual; or call

the factory service department for advice.

D A N G E R

DISCONNECT UNIT FROM

POWER SOURCE BEFORE

CLEANING OR SERVICING.

C A U T I O N

THIS SECTION IS PROVIDED FOR THE ASSISTANCE

OF QUALIFIED SERVICE TECHNICIANS ONLY AND

IS NOT INTENDED FOR USE BY UNTRAINED OR

UNAUTHORIZED SERVICE PERSONNEL.

This manual is related to the following products: