1200-S, 1200-UP •

INSTALLATION

/

OPERATION

/

SERVICE MANUAL

-

PG

. 12

ON/OFF KEY

Press the ON/OFF key once and the power

indicator light will illuminate. Press and hold

the ON/OFF key until the LED display turns

off (at least three seconds) and power

indicator light goes out.

UP/DOWN ARROW KEY

The UP and DOWN arrow keys are used for a

variety of settings when selecting the holding

temperature. If an arrow key is pressed and

released the display will show the current set

temperature for two seconds. If an arrow key

is held (at least eight seconds), the value will

change at a rapid rate. If the arrow key is

pressed and released in rapid succession, the

set temperature will change by increments of

one degree.

ENABLE / DISABLE BEEPER

A beeper sounds when an error code is

displayed. To choose between beeper on

and beeper off mode, the control must be

off, then press and hold the DOWN arrow

key until either "ON" or "OFF" is shown

in the LED display. Release arrow key

when desired mode is displayed.

FAHRENHEIT/CELSIUS

With the control off, to choose between

Fahrenheit and Celsius, press and hold the UP

arrow key until either °F or °C is shown in

LED display. Release key when desired

setting is displayed.
The control has a four-digit LED display. When

the display is on, it will show current holding

temperature, as well as diagnostic information.

CONTROL LOCK
The warmer controls can be locked so that no

changes can be made to the set temperature.

To lock the display, press and hold the

ON/OFF key and the Up Arrow key at the

same time. The lock LED will illuminate.

When the lock LED is illuminated, additional

programming will not be functional other than

the key sequence required to unlock the panel.
To unlock the display, press and hold the

ON/OFF key and the Down Arrow key at the

same time. The lock LED will extinguish. The

panel keys will resume normal function.

°F/ °C

E L E C T R O N I C C O N T R O L S E T- U P

E L E C T R O N I C C O N T R O L O P E R A T I O N

1. Preheat at 200°F (93°C) for 30 minutes.

Press the ON key, and set the temperature to

200°F (93°) by using the UP/DOWN arrow keys.

Allow a minimum of 30 minutes preheating time

before loading the holding cabinet with food.

Closing the vents on the inside of the door will

speed the preheating process. The LED heat

indicator light will go “Out” after approximately

30 minutes preheat time, or when the air

temperature inside the unit reaches the

temperature set by the operator. The Set

indicator will light up anytime the temperature is

set or reset.

2. Load with hot food only.

The purpose of the holding cabinet is to maintain

hot food at proper serving temperature. Only hot

food should be placed into the cabinet. Before

loading the cabinet with food, use a food

thermometer to make certain all products are at

an internal temperature range of 140° to 160°F

(60° to 71°C). Any food product not within the

proper temperature range should be heated before

loading into the holding cabinet.

3. Reset the control to 160°F (71°C).

Check to make certain the cabinet door is securely

closed, and reset to 160°F (71°C) by using the

UP/DOWN keys

THIS WILL NOT NECESSARILY

BE THE FINAL SETTING.

The proper temperature range and

OPEN

or

CLOSED

door vent position will depend on the type and

quantity of product. When holding food for

prolonged periods, it is advisable to periodically

check the internal temperature of each item with

a food thermometer to assure maintenance of the

proper temperature range of 140° to 160°F

(60° to 71°C).

O P E R A T I O N