You will need the 2 included screws as well
as a Phillips screwdriver PH 2.
Illustration
Insert both detergent hoses onto the
hose fittings.
Install the dosage regulator and con-
nect using 2 screws.
Note: During installation you must
make sure that the tongues of the dos-
age regulator match up with the intend-
ed recesses in the casing.
Illustration
Slide the free end of the coiled high
pressure hose through the recesses on
the dosage regulator.
Insert the hose drum into the intakes on
the transport handle.
Insert the axle of the hand crank into the
guides.
Install the fixating plate and secure it
using 2 screws.
Press the connecting fitting from the
short high pressure hose into the brass
intake, secure with clamps.
Note: Make sure the connection nipple
is aligned correctly.
Illustration
Push the high pressure hose into the
trigger gun until it locks audibly.
Note: Make sure the connection nipple
is aligned correctly.
Check the secure connection by pulling
on the high pressure hose.
Caution
Impurities in the water can damage the
high-pressure pump and the accessories.
For protection, the use of the KÄRCHER
water filter (optional accessory, order no.
4.730-059) is recommended.
For connection values, see type plate/tech-
nical data.
Observe regulations of water supplier.
ṇ
Warning
According to applicable regulations, the ap-
pliance must never be used on the drinking
water net without a system separator. A
suitable system separator by KÄRCHER or
alternatively a system separator according
to EN 12729 type BA must be used.
Water that has flown through a system sep-
arator is no longer classified as drinking
water.
Caution
Always connect the system separator to
the water supply, never directly to the appli-
ance!
Illustration
Screw the coupling element to the wa-
ter connection on the appliance.
This high-pressure cleaner is suited to work
with the KÄRCHER suction hose with back-
flow valve (Optional accessory, order no.
4.440-238) to draw in surface water, e.g.
from water butts or ponds (see specifica-
tions for max. suction height).
Fill the suction hose with water.
Screw the suction hose into the water
connection of the appliance and insert it
into the water source (e.g. rainwater
drum).
Caution
Dry running of more than 2 minutes leads to
damage of the high-pressure pump. If the
appliance does not build up pressure within
2 minutes, switch the appliance off and pro-
ceed in accordance with the instructions in
Chapter "Troubleshooting".
Illustration
Unwind the high pressure hose com-
pletely from the hose drum. Hold on to
the transport handle during this proce-
dure.
Note: If the hand crank is in its secured
position, fold it up first.
Attach the water supply hose to the
coupling on the water connection.
Install the dosage regulator for
detergent
Install the high pressure hose drum
Connect the high pressure hose to the
trigger gun
Water supply
Water supply from mains
Drawing in water from open reservoirs
Start up
19
EN