beautypg.com

Device elements, Start up – Karcher HD 8-19-4 Cage IN User Manual

Page 15

background image

– 3

see cover page
1 Nozzle
2 Nozzle screws
3 Adapter
4 Hand blowing gun
5 Safety lever
6 Lever for hand spray gun
7 High pressure hose
8 Power switch
9 High pressure connection
10 Water connection
11 Filter
12 Output thermal valve
13 Oil level indicator
14 Oil tank
15 Spray lance

The operating elements for the cleaning
process are yellow.

The controls for the maintenance and
service are light gray.

Read the oil level display when the de-
vice is not running. The oil level must be
above the two pointers.

Cut off tip of oil container cover

Install nozzle with nozzle screw on the
spray pipe/nozzle adapter.

Connect the spray lance/nozzle adapter
to the hand spray gun.

Fasten the high pressure hose to the
high pressure connection.

Warning

The appliance may only be connected to al-
ternating current.
The appliance may only be connected to an
electrical supply which has been installed in
accordance with IEC 60364.
The voltage indicated on the type plate
must correspond to the voltage of the elec-
trical source.
The minimum fuse rating required at the
socket outlet is (see technical specifica-
tions).
The appliance should always be connected
to the electrical mains using a plug. It is for-
bidden to permanently connect the appli-
ance to the power supply. The plug is only
for mains separation.
Check the power cord with mains plug for
damage before every use. If the power cord
is damaged, please arrange immediately
for the exchange by an authorized custom-
er service or a skilled electrician.
The plug and coupling of the extension ca-
ble used must be watertight.
Use the extension cord that has an ade-
quate cross-section (see "Technical Data")
and unwind it fully from the cable drum.
Unsuitable extension cables can be haz-
ardous. Only use extension cables out-
doors which have been approved for this
purpose and labelled with a sufficient cable
cross section:

For connection values, see type plate/tech-
nical data.

According to the applicable regu-
lations, the appliance must never
be used on the drinking water net
without a system separator. Use a

suitable system separator manufactured by
Kärcher; or, as an alternative, a system
separator as per EN 12729 Type BA.

Device elements

Colour coding

Start up

Check oil level

Activate deaeration of oil container

Attaching the Accessories

Electrical connection

Water connection

Connection to the water supply

15

EN