beautypg.com

Troubleshooting – Karcher BP 1 Barrel Set User Manual

Page 17

background image

– 6

Troubleshooting

Caution

To avoid risks, all repairs and replacement of spare parts may only be carried out by au-
thorized customer service personnel.
First pull out the plug from the mains before carrying out any tasks on the machine.

Fault

Cause

Remedy

Pump runs
but does not
transport

Air in the pump

Plug in/ pull out the mains plug of the
pump a few times till the fluid gets
sucked

Suction area blocked

Pull out the mains plug and clean the
suction area

(only in manual mode) Water
level below the minimum water
level

Where possible, immerse the pump
deeper into the liquid or proceed ac-
cording to the instructions in the chap-
ter describing the preparations
necessary for automatic operation

Pressure hose is blocked

Pull out the mains plug and clean the
pressure hose

Locking tap is closed (arrow
horizontal).

Open the locking tap (arrow vertical).

Pump does
not run or sud-
denly comes
to a standstill
during opera-
tions

Power supply interrupted

Check fuses and electrical connec-
tions

Thermal protection switch in the
motor has switched off the
pump as it was overheated.

Pull out the mains plug, let the pump
cool down, clean the suction area,
prevent dry running

Dirt particles have got jammed
into the suction area

Pull out the mains plug and clean the
suction area

Pump operation stopped by
sensor

Check position of level sensor

Pumping ca-
pacity is re-
ducing

Suction area blocked

Pull out the mains plug and clean the
suction area

Pumping ca-
pacity too low

The pumping capacity depends
on the flow height, hose diame-
ter and hose length.

Keep max. flow height, see technical
data. If necessary, select a different
hose diameter or hose length.

Our Kärcher branch will be pleased to help you further in the case of questions or faults.
See address on the reverse.

17

EN