background image

– 3

1 Power cord with plug
2 Drum edge holder
3 Locking valve
4 O ring
5 Housing bowl for level switch (SBP

3800)

6 Housing cover for level switch (SBP

3800)

7 Hose coupling
8 Pressure hose
9 Hose clamp
10 Level sensor
11 Level switch attachment
12 Carrying handle
13 Hose connection G

3

/

4

(24.4 mm)

for hose coupling

14 Foam filter
15 Filter basket

Screw the hose connection on to the
pump

Connect the hose connection to the
hose coupling of the drum edge holder.

Illustration
SBP 3800 only

Screw the housing bowl and the O-ring
onto the drum edge holder.

Place the level switch into the housing
bowl.

Press the housing cover down onto the
housing bowl until it locks.

Illustration

Slide the drum edge holder onto the
container edge until it is properly seat-
ed.

Illustration

Place the pump on a stabil surface in
the liquid to be transported. Immerse it
using a rope tied to the handle or hang
it into the container by the hose.
The suction area should not be blocked
fully or partially through the impurities.

Illustration

Close locking tap (arrow horizontal).

Illustration

In automatic operation, set the required
switching height by clamping the level
switch cable into the stopper.

Illustration

In manual operations mode, align the
level sensor upward (cable pointing
downward). Tip: Push the cable of the
level sensor like a loop through the han-
dle.

Note:
When using the SBP 3800, the level switch
can be placed inside the housing bowl (Fig-
ure 1).

Screw the hose connection G 3/4 (24.4
mm) for the 3/4“ (19 mm) hose onto the
pump (not included in the delivery).

Slide the hose onto the hose connec-
tion and fasten it with an appropriate
hose clamp.

Note:
A short hose and a large hose diameter
yield a high volume.
Illustration

In automatic operation, set the required
switching height by clamping the level
switch cable into the stopper.

Illustration

In manual operations mode, align the
level sensor upward (cable pointing
downward). Tip: Push the cable of the
level sensor like a loop through the han-
dle.

Operation

Description of the Appliance

Preparing the drum pump operation

Different uses of the level switch

Preparing the immersion pump op-

eration

14