Operation – Karcher BP 1 Barrel Set User Manual
Page 14

– 3
1 Power cord with plug
2 Drum edge holder
3 Locking valve
4 O ring
5 Housing bowl for level switch (SBP
3800)
6 Housing cover for level switch (SBP
3800)
7 Hose coupling
8 Pressure hose
9 Hose clamp
10 Level sensor
11 Level switch attachment
12 Carrying handle
13 Hose connection G
3
/
4
(24.4 mm)
for hose coupling
14 Foam filter
15 Filter basket
Screw the hose connection on to the
pump
Connect the hose connection to the
hose coupling of the drum edge holder.
Illustration
SBP 3800 only
Screw the housing bowl and the O-ring
onto the drum edge holder.
Place the level switch into the housing
bowl.
Press the housing cover down onto the
housing bowl until it locks.
Illustration
Slide the drum edge holder onto the
container edge until it is properly seat-
ed.
Illustration
Place the pump on a stabil surface in
the liquid to be transported. Immerse it
using a rope tied to the handle or hang
it into the container by the hose.
The suction area should not be blocked
fully or partially through the impurities.
Illustration
Close locking tap (arrow horizontal).
Illustration
In automatic operation, set the required
switching height by clamping the level
switch cable into the stopper.
Illustration
In manual operations mode, align the
level sensor upward (cable pointing
downward). Tip: Push the cable of the
level sensor like a loop through the han-
dle.
Note:
When using the SBP 3800, the level switch
can be placed inside the housing bowl (Fig-
ure 1).
Screw the hose connection G 3/4 (24.4
mm) for the 3/4“ (19 mm) hose onto the
pump (not included in the delivery).
Slide the hose onto the hose connec-
tion and fasten it with an appropriate
hose clamp.
Note:
A short hose and a large hose diameter
yield a high volume.
Illustration
In automatic operation, set the required
switching height by clamping the level
switch cable into the stopper.
Illustration
In manual operations mode, align the
level sensor upward (cable pointing
downward). Tip: Push the cable of the
level sensor like a loop through the han-
dle.
Operation
Description of the Appliance
Preparing the drum pump operation
Different uses of the level switch
Preparing the immersion pump op-
eration
14
EN