Î

Oil change.

Note
See "Technical Details" for details of oil
quantity and type.
Î

Turn out the oil drain screw at the front
on the motor casing.

Î

Drain the oil in a collection basin.

Î

Turn out the oil drain screw.

Î

Fill in new oil slowly; air bubbles should
go out.

Î

Attach the lid of the oil container.

Î

Fasten the device hood.

ƽ

Danger

First pull out the plug from the mains before
carrying out any tasks on the machine.
Get the electrical components checked and
repaired only by authorised customer serv-
ice persons.
Contact an authorised customer service
person in case of problems not mentioned
in this chapter or if you are in doubt or when
you have been explicitly asked to do so.

Î

Check connection cable for damages.

Î

Call Customer Service in case of elec-
trical defects.

Î

Install the high pressure nozzle.

Î

Clean/ replace nozzle.

Î

Clean the fine filter; replace it, if neces-
sary.

Î

Deaerate the appliance (see "Start-up")

Î

Check water supply level (refer to tech-
nical data).

Î

Check all inlet pipes to the pump.

Î

Contact Customer Service if needed.

3 drops per minute are permitted and can
come out from the lower side of the appli-
ance. Call Customer Service if there is
heavy leakage.
Î

With stronger leak, have device
checked by customer service.

Î

Check suction pipes for water and de-
tergent and ensure that they are leak-
proof.

Î

Deaerate the appliance (see "Start-up")

Î

Clean the fine filter.

Î

Contact Customer Service if needed.

monthly or after 500 operating

hours

Oil change

Troubleshooting

Appliance is not running

Pressure does not build up in the

appliance

Pump leaky

Pump is vibrating

Detergent is not getting sucked in