Troubleshooting, Technical specifications – Karcher SC 1-010 User Manual
Page 21
– 12
fore, you should rinse the boiler two to
three times with cold water to remove
any residues of the descaler.
Completely empty the steam boiler to
remove existing water (see fig. ).
Note: The floorcloth and the terry cloth cov-
er have been pre-washed and can be used
immediately for working with the steam
cleaner.
You can wash dirty floorcloths and terry
cloth covers in the washing machine at
60°C. Do not use a liquid softener as
this would affect the ability of the cloths
to pick up dirt. You may tumble dry the
cloths.
Often, failures have simple causes and you
can do the troubleshooting yourself using
the following overview. If you are in doubt
or if the failure is not listed here please con-
tact the authorized customer service.
ƽ
Danger
Always disconnect the mains plug and al-
low the steam cleaner to cool down before
performing any maintenance work.
Repair works may only be performed by the
authorized customer service.
Descale the steam boiler.
Turn off the appliance.
See „Refilling Water“ Page 9.
Steam switch is secured with the lock /
child-proof lock.
Push the steam switch lock to the back.
Press the steam gun until less water is
emitted.
Descale the steam boiler.
Subject to technical modifications!
Care of the Accessories
Troubleshooting
Long heating-up time
Steam boiler is decalcified
No steam
No water in the steam boiler.
Steam lever cannot be pressed anymore
High water output
Steam chamber too full
Steam boiler is decalcified
Technical specifications
Power connection
Voltage
220-240
1~50/60
V
Hz
Protective class
I
Protection class
IPX4
Performance data
Heating output
1500 W
Operating pressure max.
0,32 MPa
Heating time
per litre of water
8 Min-
utes
Steam volume
Continuous steaming
40 g/min
Steam push max.
100 g/min
Dimensions
Boiler capacity
1,0 l
Weight (without acces-
sories)
3,4 kg
Width
250 mm
Length
381 mm
Height
260 mm
21
EN