beautypg.com

Troubleshooting, Technical specifications – Karcher SC 3-100 B User Manual

Page 22

background image

– 13

Note: The floorcloth and the terry cloth cov-
er have been pre-washed and can be used
immediately for working with the steam
cleaner.

You can wash dirty floorcloths and terry
cloth covers in the washing machine at
60°C. Do not use a liquid softener as
this would affect the ability of the cloths
to pick up dirt. You may tumble dry the
cloths.

Often, failures have simple causes and you
can do the troubleshooting yourself using
the following overview. If you are in doubt
or if the failure is not listed here please con-
tact the authorized customer service.

ƽ

Danger

Always disconnect the mains plug and al-
low the steam cleaner to cool down before
performing any maintenance work.
Repair works may only be performed by the
authorized customer service.

Descale the steam boiler.

Turn off the appliance.

See „Refilling Water“ Page 9.

Steam switch is secured with the lock /
child-proof lock.

Move the selector switch for the steam
volume to the front.

Set the thermostat to level •••.

Rinse or decalcify the boiler of the

steam cleaner.

During longer breaks from ironing, the
steam in the steam line can condense.

Direct the first burst of steam at a sepa-
rate piece of cloth.

Press the steam gun until less water is
emitted.

Descale the steam boiler.

Subject to technical modifications!

Care of the Accessories

Troubleshooting

Long heating-up time

Steam boiler is decalcified

No steam

No water in the steam boiler.

Steam lever cannot be pressed
anymore

Steam iron "spits out" water!

After breaks during ironing, water drops
will come out of the steam pressure iron.

High water output

Steam chamber too full

Steam boiler is decalcified

Technical specifications

Power connection
Voltage

220-240 V

1~50/60 Hz

Protective class

I

Protection class

IPX4

Performance data
Heating output

1800 W

Heating output steam
iron

700 W

Operating pressure
max.

0,35 MPa

Heating time

6 Minutes

Steam volume
- Continuous steaming

50 g/min

- Steam push max.

110 g/min

Dimensions
Boiler capacity

1,0 l

Weight (without acces-
sories)

3,1 kg

Width

250 mm

Length

382 mm

Height

256 mm

22