– 7

The appliance must not be carried dur-
ing cleaning.

The appliance must provide of a stable
ground.

Use and store the unit only in accord-
ance with the specifications in the de-
scription and/or figure.

The steam switch must not be locked
during the operation.

Protect the appliance from rain. Do not
store outside.

Caution
Safety devices protect the user and must
not be modified or bypassed.

The pressure controller keeps the boiler
pressure during the operation as constant
as possible. The heating is turned off if the
maximum operating pressure of 4 bar is
reached in the boiler and is reactivated in
case of a pressure drop in the boiler due to
steam tapping.

If, in case of a malfunction, there is no wa-
ter in the boiler, the temperature in the boil-
er rises. The boiler thermostat turns off the
heating. Once the boiler is filled, normal op-
eration can continue.

The safety thermostat turns off the appli-
ance if the boiler thermostat and the pres-
sure controller fails and the appliance
overheats in case of a malfunction. Please
contact your local KÄRCHER customer
service to arrange for the reset of the safety
thermostat.

The maintenance lock acts as a pressure
control valve at the same time. It seals the
boiler against the steam pressure that
builds up in the boiler.
If the pressure controller is defect and the
steam pressure in the boiler rises, the pres-
sure control valve, and steam is emitted
through the maintenance lock to the out-
side.

Please contact your local KÄRCHER cus-
tomer service before you put the appliance
into operation again.

These operating instructions describe the
maximum equipment. Depending on the
model, there are differences in the scopes
of delivery (see packaging).

Illustrations on fold-out
page!

Safety Devices

Pressure controller

Boiler thermostat

Safety thermostat

Maintenance lock

Description of the Appliance

A1 Appliance connector with cover
A2 Water reservoir
A3 Locking door for water reservoir
A4 Switch - ON/OFF
A5 Indicator lamp - heating (GREEN)
A6 Indicator lamp "water shortage" (RED)
A7 Carrying handle
A8 Holder for accessories
A9 Accessory compartment with locking

door

A10 Maintenance lock
A11 Storage for mains connection cable
A12 Storage holder for floor nozzle
A13 Mains cable with mains plug
A14 Running wheels (2 ea.)
A15 Steering roller
B1 Steam gun
B2 Steam lever
B3 Unlocking button
B4 Selector switch for the steam volume

(with child protection)

B5 Steam hose
B6 Steam plug
C1 Detail nozzle
C2 Round brush
C3 Power nozzle
D1 Hand nozzle
D2 Terry cloth cover
E1 Extension tubes (two tubes)
E2 Unlocking button
F1 Floor nozzle
F2 Retaining clip
F3 Terry floor cloth
G1 Window wiper
Option
H1 Steam pressure iron
H2 Upper steam button
H3 Indicator lamp - heater (ORANGE)
H4 Lower steam button