Karcher HD 9-50-4 User Manual
Page 22
– 8
The indicator lamps display the operating
states (green) and interruptions (red).
Reset:
Set the appliance switch to "0".
Wait for a while.
Set the appliance switch to "I".
Continuous green:
–
The appliance is now ready for opera-
tion.
1x blinking green:
–
Operational readiness has expired after
30 minutes.
–
The appliance has switched off after 30
minutes of continuous operation (safety
if the high pressure hose bursts).
Continuous red light:
–
Electrical problems in appliance
Pull out the mains plug.
Call Customer Service.
1x blinking red:
–
High pressure side is leaky
Check high pressure hose, hose con-
nections and hand spray gun for leaks.
2x blinking red:
–
Engine overload/overheat
Set the appliance switch to "0".
Allow device to cool down.
Set the appliance switch to "I".
–
Water pressure is too low
Ensure adequate water line pressure.
3x blinking red:
–
Fault in the voltage supply
Check main connections and mains
fuse.
4x blinking red:
–
Power consumption is too high
Call Customer Service.
–
No power
Check whether the voltage indicated on
the type plate corresponds to the volt-
age of the socket.
Check the mains connection cable for
damages.
–
Indicator lamp is blinking green
Operational readiness period has ex-
pired. Switch on/off the appliance
again.
–
The water shortage fuse (option) was
triggered due to low water inlet pres-
sure.
The indicator lamp "lack of water" will il-
luminate.
Check water inlet pressure, minimum
value see "Specifications".
Turn the device switch to "0" and turn
on again to restart the system.
–
Motor overloaded/ over-heated or elec-
trical circuit breaker or winding protec-
tion switch has got released.
Switch off appliance and let it cool
down. Remove the cause of the prob-
lem. Turn on the appliance again.
–
Wrong nozzle
Check nozzle for correct size (see tech-
nical specifications).
–
Flushed the nozzle.
Clean/ replace nozzle.
–
Filter is dirty.
Clean filter at the water connection.
Unscrew the filter casing, remove the
filter, clean it and replace it.
–
Air within the system
Appliance ventilation:
Unscrew the nozzle. Switch on the ap-
pliance and let it run until the water ex-
iting from the spray pipe is bubble-free.
Switch off the appliance and fit the noz-
zle again.
–
Pipe inlets to pump are leaky or blocked
Check all supply lines to the pump for
leaks or blockages.
Indicator lamp
Operating status display
Fault indication
Appliance is not running
Device is not building up pressure
22