beautypg.com

Troubleshooting – Karcher NT 75-1 Tact Me Te H S Z2 User Manual

Page 25

background image

– 8

Illustration

Pull the safety filter sack over the con-
tainer.

Insert and lock the suction head.

Release and remove the suction head.

Clean the electrodes with a brush.

Insert and lock the suction head.

Illustration

Insert 2 flat-tip screwdrivers up to the
stop in the filter casing openings on the
suction head.

Push both flat-tip screwdrivers down
and lever out the filter casing.

Remove the filter casing.

Remove the supply air filter from the fil-
ter casing.

Install new supply air filter into the filter
casing.

Insert filter casing in the suction head
and snap in place.

ƽ

Danger

First pull out the plug from the mains before
carrying out any tasks on the machine.

Warning

All checking and work on electrical parts
must be performed by an authorized elec-
trician. In the event of continuing faults,
contact Kärcher customer service.
Note: In case of a failure (e.g. filter break-
age) the appliance must be turned off im-
mediately. The failure must be remedied
before the appliance is put into operation
again.

Check the receptacle and the fuse of
the power supply.

Check the power cable, the power plug
and electrodes of the device.

Turn on the appliance.

Empty the container.

Turn off the appliance and wait for 5
seconds, turn it on again after 5 sec-
onds.

Clean the electrodes as well as the
space between the electrodes with a
brush.

Remove blockages in the suction noz-
zle, suction tube, suction hose, or flat
pleated filter.

Replace the safety filter sack.

Ensure the filter cover properly locks
into place.

Replace the flat pleated filter.

Thermal protection device has switched
the motor into the emergency mode due
to overheating.

Allow appliance to cool down. Replace
the supply air filter.

Check for proper installation of the flat
pleated filter.

Replace the flat pleated filter.

Clean the electrodes as well as the
space between the electrodes with a
brush.

Continuously check the filling level in
case of non-conductive liquid.

Replace the flat pleated filter.

The safety filter sack must be replaced
when it is full and the minimum volume
flow is fallen short of.

Cleaning the electrodes

Replacing the supply air filter

Troubleshooting

Suction turbine does not run

Suction turbine turns off

Suction turbine does not start again

after the container has been

emptied

Suction capacity decreases

Dust comes out while vacuuming

Automatic shut-off (wet vacuum

cleaning) does not react

Indicator lamp "negative pressure"

lights up red

25

EN