Operation – Karcher HDS 5-11 UX User Manual
Page 20
– 4
ṇ
Warning
Observe regulations of water supplier.
According to the applicable regula-
tions, the appliance must never be
used on the drinking water supply
without a system separator. Use a
suitable system separator manufactured by
KÄRCHER; or, as an alternative, a system
separator as per EN 12729 Type BA. Water
flowing through a system separator is con-
sidered non-drinkable.
Caution
Always connect the system separator to
the water supply, never directly to the appli-
ance!
For connection values refer to technical
specifications
Attach supply hose (minimum length
7.5 m, minimum diameter 1/2“) to the
water supply set by means of a hose
clamp.
Connect the supply hose to the water
connection point of the machine and at
the water supply point (for e.g. a tap).
Note: The supply hose and the hose clamp
are not included in the scope of delivery.
Connect suction hose (minimum diame-
ter 1/2“) with filter (accessory) to the
water connection point.
–
Max. suck height: 0.5 m
ƽ
Danger
Never suck in water from a drinking water
container. Never suck in liquids which con-
tain solvents like lacquer thinner, petrol, oil
or unfiltered water. The sealings within the
device are not solvent resistant. The spray
mist of solvents is highly inflammable, ex-
plosive and poisonous.
–
For connection values, see technical
data and type plate.
–
The electrical connections must be
done by an electrician according to IEC
60364-1.
Set the appliance switch to "0/OFF“.
Plug in the main plug.
ƽ
Danger
Danger of injury by electric shock.
–
Unsuitable extension cables can be
hazardous. Only use extension cables
outdoors which have been approved for
this purpose and labelled with a suffi-
cient cable cross section:
–
Always unwind extension lines com-
pletely.
–
The plug and coupling of the extension
cable used must be watertight.
Caution
The highest allowed net impedance at the
electrical connection point (refer to techni-
cal data) is not to be exceeded. In case of
confusion regarding the power impedance
present on your connection, please contact
your utilities provider.
ƽ
Danger
Risk of explosion!
Do not spray flammable liquids.
Caution
–
Never operate device with empty fuel
tank The fuel pump will otherwise be
destroyed. This also applies to cold wa-
ter operation.
–
Risk of damage! Never operate the ap-
pliance without a filter in the water con-
nection.
–
Risk of damage! Do not place any ob-
jects (hose,etc.) on or over the chim-
ney.
–
Device with hose drum:
Always unwind high pressure hose
completely
Water connection
Suck in water from vessel
Power connection
Operation
20
EN