The appliance may only be connected to an
electrical supply which has been installed
by an electrician in accordance with IEC
60364.
For connection values, see type plate/tech-
nical data.
You are not allowed to use an extension ca-
ble.
ƽ
Danger
Risk of electric shock. Electrical connecting
cables must not be damaged through being
driven over, crushed, pulled or the like. Pro-
tect the power cord from heat, oil, and
sharp edges.
Check the mains cables of the machine
each time before using the machine to see
that it is not damaged. Never operate a ma-
chine with damaged cables. Get the dam-
aged cables replaced by an electrician.
ṇ
Warning
The highest allowed net impedance at the
electrical connection point (refer to techni-
cal data) is not to be exceeded.
In case of confusion regarding the power
impedance present on your connection,
please contact your utilities provider.
1 Brake rollers
2 Accessory basket
3 Electrical box, mains switch and indica-
tor light
4 Hinge with stop bolt
5 Suction hose connection
6 Switching valve
7 Safety pin for switching valve
8 Lock latches, tensioning clamps
9 Knee lever for switching valve
10 Cable and hose storage
11 Push handle
12 Return hose with ball valve
Electrical connection
Operation
Control elements
11